Page 1: ...Operation Manual SSB10 SSB13 SSB16 SSB20 SSB25 SSB30 SSB35 SSB40 SAMSUNG BOILER CO LTD http www smart g net 1 ...
Page 2: ...l Heating ㆍ Bath ㆍ Useful functions Cleaning and Maintenance ㆍ Cleaning ㆍ Measures when safety device is on ㆍ Product specifications ㆍ Before ask for service Installation ㆍ Drawing of overview ㆍ Air supply exhaust pipe installation ㆍ How to install remote controller ㆍ Test running Indemnity Warraty We strongly recommend that you carefully read the user manual for proper usage including details on ...
Page 3: ...ger Do not touch Prohibitive Warning Caution Caution Inflammable Must do Electric wiring must be grounded Gas Leakage ㆍCheck if gas leakage is detected Frequently check using liquid soap around gas pipe connector if gas is leaked Must do ㆍWhenever gas leakage detected do not panic and follow our instruction as below Close intermediate valve Close the Open the Open the door or window for ventilatio...
Page 4: ...bent ㆍExhaust gas from connector between product and ventilation shaft can cause CO gas poisoning ㆍIf you have a problem in ventilation shaft Must do call for supplier and ask repair before use Warning Caution Check your supply power ㆍThis product is designed to be used for 220V 50Hz it must be connected to wiring grounded power outlet Do not bend cut or extend power cord Must do ㆍElectroshock or ...
Page 5: ...t pipe due to burn your skin Do not touch Do not separate connector of exhaust pipe ㆍIf exhaust gas indraft into indoor it will happen to gas poisoning Must do Do not use for other purposes except heating water ㆍDo not use an auxiliary tools either There could be a breakdown in product or unexpected accident Prohibitive Do not block ventilating opening ㆍIf you block indoor ventilating opening usin...
Page 6: ...Identification of components Exhaust Pipe Pressure Gauge Heating Outlet Hot Water Outlet Gas Inlet Cold Water Inlet Heating Return Water Filling Valve 6 ...
Page 7: ...sion Tank Hot water flow Switch Ignition Plug Aps Switch Three way Motor 2nd Heat Exchanger Pressure Gauge Gas Valve Flow detector Circulation Pump Safety valve Hose Main Controller Exhaust Fan Burner 1st Heat Exchanger 7 ...
Page 8: ...h Only Checkup Hot water Temperature Current Temperature Bath On Freeze Protection On Off Going Out Heating Interval Heating On Off Components Please check that all components listed below are included in the package Remote Controller Indoor Thermostat Bracket to Hold remote Controller User s Manual Screws for Mounting Remote Controller Bracket Temperature Button Check Lamp 8 ...
Page 9: ...ng Hot Water button and Present Room Temperature How to set room temperature Press Heating HotWater button for 3 seconds When Room Temperature flickers set the room temperature using the Up or Down buttons Press Heating Hot Water button again or wait for 5 seconds and the heating temperature is automatically set Temperature Setting Floor Heating Temperature Steps Press Up button and the temperatur...
Page 10: ... Floor Heating Press the Heating Interval Setting button for 3 seconds When the Heating Interval display flickers select the heating interval you want Set the heating interval using Up or Down button Press the Heating Interval Setting button Or wait for 5 seconds and the Heating Interval is automatically set What is Heating Interval When the heating interval is set to 20 minutes the boiler works f...
Page 11: ...on for 5 seconds and the hot water temperature is automatically set Turn the hot water tap and the Bath display on the remote controller flickers Then the boiler is ignited and hot water is supplied after a while Press the Hot Water Temperature Setting button to set the temperature 30 C 60 C Setting by the unit of 1 C When the Heating display is on heating and bath function are activated If only B...
Page 12: ...er when away from home long time in cold weather Exposed pipe must be wrapped with insulating materials Put additional heat wire on water supply pipe or hot water supply pipe and wrap using insulating materials to prevent freezing Must do Caution Check if there is deformation on product or deformation over ventilating shaft And check if ventilating shaft is come off from product If exhaust gas lea...
Page 13: ...e E8 Disconnection or short circuit of heating temperature sensor Boiling safety device for heating E9 Heating water temperature 95 C Outdoor thermostat failure EA Disconnection or short circuit of sensor Residual flame detection quasi flame Eb Residual flame or flame sensor failure in the combustion chamber before or after activation Poor communication EC Communication failure between main circui...
Page 14: ...ressur e in 0 5 3 0 Max Temp in setting 35 80 Dimensions W L H mm 490 230 660 490 350 660 Weight Kg 30 7 31 8 32 5 34 9 35 4 Connecti on Dim Inlet outlet Heating A 20 20 Inlet outlet Hot water 15 15 Gas Connecti on 15 20 Exhaust Inlet Dim FF mm Funnel ø60 100 Funnel ø75 100 Specifications Forced balanced flue sealed combustion chamber Model Content SSB10 SSB13 SSB16 SSB20 SSB25 SSB30 Heated Area 3...
Page 15: ...te valve if there was not the gas change new one In case of LP liquefied petroleum gas Make a strange noise 1 Mount boiler on wall well 2 Is exhaust pipe clogged or not 1 Make sure to mount gas boiler on the wall 2 In case of making a strange noise after fixed special service is required Hot water does not come out 1 Water supply valve s not open 2 Water supply filter is clogged 3 Water flow rate ...
Page 16: ...or deposits accumulated by using underground water To prevent of this situation clean pipe completely ㆍOnce installation is completed return this manual to user Before the installation ㆍCheck up the type of supply gas and electricity Please install according to product specification Safety valve operation Drain method The water drained automatically through the drain pipe if inner Pressure of boil...
Page 17: ...n Do not install near the heat appliance ㆍTake a distance 1 000mm over the other heat appliance Avoid the hot air ㆍTake a distance 300mm over the power outlet Caution of combustible materials ㆍDo not put any combustiable material near by boiler gasoline thinner sulfer match etc Installation to the inflammable wall ㆍTake a distance of 45mm if there is inflammable wall both side ㆍWhen you install on...
Page 18: ...Installation 18 ...
Page 19: ... water Outlet Gas Inlet Cold water Inlet Install butterfly valve for each valve Open the every distribution point such as Water Pipe Gas Pipe etc to protect freezing in cold weather during away from home for long period Do not cut off Gas and Electricity Pipework 19 ...
Page 20: ...ltage to 220V grounding must be done In this case allowed transmitter capacity is 1kW h more Gas pipe Telephone Line 1 The material of gas joint between gas heater and gas piping should use for the approval of good qualifications standard certified 2 Connect with pipe diameter of 15A PT1 2 to RW 14 RW 18 Model Connect with pipe diameter of 20A PT1 2 to RW 24 Models 3 Finishing the connection Must ...
Page 21: ...ickness 25mm over Cold area 50mm over ㆍEspecially the surface of hot water heating pipe have to installed heat wire to prevent from severe cold winter Heat wire must be purchase only ㆍDo not wrap the drain knob and filter with insulating material In case of installation of automatic water pumping due to low water pressure Warning product should not be installed in the exclusive place Otherwise fir...
Page 22: ...t pipe and return pipe Install drain valve at lowest place of pipe and making pipe in order to drain of all of heating water when necessary Must not install the valve at middle part of hose It may have overflow the water and may have damage due to flood Make room heating piping using hot water distributor and install auto or manual air outlet at top part of distributor and let air out in the pipe ...
Page 23: ...let outlet and ventilating opening at the top are required The air inlet outlet and ventilating opening at the top must be made in a place that prevents the exhaust gas from escaping the top of the exhaust tube This includes outdoor spaces or well ventilated aisles The effective area of air inlet outlet or ventilating opening at the top must be bigger than the cross section of the exhaust tube Ope...
Page 24: ...ot exceed more than 13meter In case of installing reclaiming work ㆍIn case install exhaust pipe as filling in part inside of ceiling and etc connect each part securely and wrap with incombustible material except metal type so no gas leakages Be sure to seal each connection part with aluminum tape ㆍTo examine and fix air supply exhaust pipe in dark areas install examination openings Vertical Length...
Page 25: ... short circuit or leakage current If this occurs the boiler may not work properly Do not bind or put the AC220V power wire including other electric appliances and the remote controller wire into the conduit tube for underground installation The remote controller may be influenced by electrical noise The remote controller has no positive or negative pole Strongly cover the joints using the insulati...
Page 26: ...e remote controller causing it to not mount on the bracket To pull the remote controller wire from the bottom of the remote controller pull the wire between the opening at the bottom center of the remote controller and the opening at the bottom of the bracket Mounting on Switch Box Separate the bracket from the remote controller and fix the bracket using the flat head screws contained in the packa...
Page 27: ... opened Turn Heating on and get the set temperature down Turn Heating on using the remote controller and set the Hot Water temperature Open the hot water valve and check if hot water comes out Fasten the hot water valve If heating is not required turn Heating off Fill water until the pressure gauge indicates 0 5 1 5kgf cm2 Or drain water by releasing air Visually check leakage from joints of water...
Page 28: ...or clogged Are there any flammables Item Procedure Remarks 3 Drain Pipe Installation Check Connect the drain hole on the bottom left of the boiler to the drain pipe using the flexible hose Do not connect the shut off valve to the flexible hose above If the drain hose is not connected to the drain pipe water from the boiler may cause flooding 4 Finishing Check if heating system is completely instal...
Page 29: ...Wiring Parameter setting 30K 35K 40K 10K 13K 16K 29 ...
Page 30: ...k EA 1 SSB 30K 35K 40K 3 SSB1040ML0001A Heating Temperature Sensor EA 1 SSB 10K 40K 4 DHW Temperature Sensor EA 1 SSB 10K 40K 5 SSB1040ML0002A Main Controller EA 1 SSB 10K 40K 6 SSB1040ML0003A Circulation Pump EA 1 SSB 10K 40K 7 SSB1040ML0004A Exhaust Fan DC EA 1 SSB 10K 13K 16K 20K 25K 30K 35K 40K 8 SSB1025ML0002A Gas Valve Set 15A EA 1 SSB 10K 13K 16K 20K 25K 30 ...
Page 31: ...35K 40K 12 SSB1040ML0005A 2nd Heat Exchanger DHW EA 1 SSB 10K 13K 16K 20K 25K 30K 35K 40K 13 SSB1040ML0006A Burner EA 1 SSB 10K 13K 16K 20K 25K 30K 35K 40K 14 SSB1040ML0009A Three Path Motor EA 1 SSB 10K 40K 15 SSB1040ML0010A Pressure Relief Valve EA 1 SSB 10K 40K 16 SSB1040ML0011A Water Pressure Meter EA 1 SSB 10K 40K 17 SSB1040ML0012A Water Flow Switch EA 1 SSB 10K 40K 31 ...
Page 32: ...14A Ignition Components EA 1 SSB 10K 40K 20 SSB1040ML0015A 95 Thermostat EA 1 SSB 10K 40K 21 SSB1040ML0019A Room Controller EA 1 SSB 10K 40K 22 SSB1040ML0036A Flow Detector EA 1 SSB 10K 40K 23 SSB1040ML0037A Nozzle holder LPG Set 1 SSB 10K 13K 16K 20K 25K 30K 35K 40K 32 ...
Page 33: ...in 5th occurrence If the replaced part requires a critical repair within one month after replacement Repair without any payment Replacement of product or refund Refund Replacement of product or refund Replacement of product or refund Refund 3 Damage caused by the Company keeping no components for repair within the compulsory holding period for components Within the warranty period Performance or f...
Page 34: ...od 1 Failure occurred intentionally or by mistake 2 Failure by natural disasters 3 If there are no contents on this Warranty or this Warranty is lost 4 Failure caused by using improper electric capacity For service request 1 Fill out the Warranty form when you purchase the product check the details and keep the Warranty 2 Show the Warranty to a service engineer when the service engineer visits for...
Page 35: ...35 Home Page http www smart g net Address 75 Seokmun gil Seonggeo eup Seobuk gu Cheonan si Chungcheongnam do Korea Tel 82 41 583 7200 7211 7213 FAX 82 41 583 7500 wwww smartboiler net ...