Hardware Preparation and Installation
RTM-ATCA-736x-10G Installation and Use (6806800P29G)
29
During the safety qualification of this product, the following on-board locations were
identified as critical with regards to the maximum temperature during blade operation. To
guarantee proper product operation and to ensure safety, you have to make sure that the
temperatures at the locations specified in the following are not exceeded. If not stated
otherwise, the temperature should be measured by placing a sensor exactly at the given
locations. For your convenience all temperature spots are shown in the figure below that
provides a detailed view of the product.
Shock
(with HDD
Installed)
Half-sine, 11m/Sec, 30mSec/Sec
2
Blade level packaging
Half-sine, 6mSec at 180m/Sec
2
Free Fall
-
1,200 mm/all edges and corners
1.0 m (packaged) per ETSI 300 019-2-2
(blade level packaging)
100 mm (unpacked) per GR-63-CORE
Table 2-1
Environmental Requirements (continued)
Requirement Operating
Non-Operating
Table 2-2
Critical Temperature Limits
Location
Component
Temperature Limit
U3, U40, U52
Dual Port 10 Gigabit Ethernet Controllers
70 °C
U59
Quad Gigabit Ethernet LAN Controller
70°C
U55
Four Port SAS Controller
70°C
U36
Four Port PCI Express Switch
70°C
Temperature limit is valid when measured on the component heat sink.
Summary of Contents for RTM-ATCA-736x-10G Series
Page 1: ...RTM ATCA 736x 10G Installation and Use P N 6806800P29G December 2020...
Page 6: ...List of Figures 6 RTM ATCA 736x 10G Installation and Use 6806800P29G...
Page 8: ...List of Tables 8 RTM ATCA 736x 10G Installation and Use 6806800P29G...
Page 14: ...14 RTM ATCA 736x 10G Installation and Use 6806800P29G About this Manual About this Manual...
Page 57: ...1...