EN
EN
Operating Instructions
Icon
Operation
Meaning
Arm
Press this button, and the control panel beeps once,
indicating the whole system is armed.
Disarm
Press this button, and the control panel beeps twice,
then the system is disarmed except those sensors in
the 24-hour zone.
Stay
Press this button, all the sensors in home mode will
enter disarm status. While other sensors remain in
arm status, then user can move freely in the home
zone.
SOS
SOS
Press this button, the system will enter into the alarm
state immediately.
+
Mute Arm
Press the
[Stay ]
button for 1 second, wait until its
indicator flashes once then press the
[Arm ]
button
within 3 seconds, the system is armed silently.
+
Mute Disarm
Press the
[Stay ]
button for 1 second, wait until its
indicator flashes once then press the
[Disarm ]
button within 3 seconds, the system is disarmed
silently.
Specifications
Power Supply:
DC 3 V (CR2032 lithium button cell battery x 1)
Transmit Current:
<9.5 mA
Transmitting Distance:
<80 m (Open area/no interference)
Radio Frequency:
868 MHz
Housing Material:
PC+ABS plastic
Operation Condition:
Temperature: 0 °C ~ +55 °C
Relative Humidity: <80% (non-condensing)
Dimensions:
71 × 38 × 12 mm