Smalvic AI-45BT LX12-ETCR INOX Use And Maintenance Manual Download Page 8

E

N

G

L

IS

H

E

N

G

L

IS

H

E

N

G

L

IS

H

E

N

G

L

IS

H

 

 

8

 

9880028100-EN-240314 

SHARED DISPLAY 

 

TIME display 

 

CLOCK display 

 

TEMPERATURE display 

 

 

OPERATION display 

 

TIMER icon 

 

ALARM icon

 

 

PROGRESSIVE TIME icon

 

 

CYCLE DURATION icon

 

 

BLAST CHILLING icon

 

 

DEEP FREEZING icon

 

 

BLAST CH3° C icon

 

 

DEEP FREEZING -18° C icon

 

 

HARD icon

 

 

NEEDLE PROBE icon

 

 

DEFROST icon

 

 

PRECOOLING icon

 

 

BOTTLE icon

 

 

AUTOMATIC PROGRAM icon

 

 

FISH icon

 

 

MANUAL icon

 

 

STORAGE icon

 

 

KEYPAD LOCK icon 

 

PROOFING icon 

 

HEATING icon 

 

 

 

 

 

APPLIANCE STARTUP DESCRIPTION 

SETTING CLOCK AT FIRST STARTUP 

When first hooked up to the mains, the clock is as shown in the figure 

, with the hours flashing. 

To  set  the  time  (in  the  version  with  knobs),  turn  the  knob 

  until  you  see  the  desired  value  and  press  the 

 key to confirm. Perform the same procedure for the minutes. 

In models without knobs, use the 

 and 

 keys to select the desired value and the 

 key to confirm. 

 

SETTING CLOCK 

Changes to the clock are made with the unit in stand-by (see relevant paragraph). 

Hold down the 

 for at least 3 seconds. The hours will flash. 

To  set  the  time  (in  the  version  with  knobs),  turn  the  knob 

  until  you  see  the  desired  value  and  press  the 

 key to confirm. Perform the same procedure for the minutes. 

In models without knobs, use the 

 and 

 keys to select the desired value and the 

 key to confirm. 

 

BLACKOUT - POWER FAILURE 

Summary of Contents for AI-45BT LX12-ETCR INOX

Page 1: ...MAINTENANCE MANUAL FOR BLAST CHILLERS USE AND MAINTENANCE MANUAL FOR BLAST CHILLERS USE AND MAINTENANCE MANUAL FOR BLAST CHILLERS QUICK FREEZERS QUICK FREEZERS QUICK FREEZERS QUICK FREEZERS MODELS MOD...

Page 2: ...ACKOUT POWER FAILURE 8 ACTIVATION AND SHUTDOWN ON OFF 9 DESCRIPTION OF PROGRAMS 9 SAVED PROGRAMS 9 SELECTING SAVED PROGRAMS 11 STARTING A SAVED PROGRAM 11 CHANGING SETTINGS IN AN EDITABLE PROGRAM 12 C...

Page 3: ...or damp hands or feet Inserting kitchen tools or other objects between the fan protections or aspiration vents Using the blast chiller to store objects when it is not in use otherwise damage could be...

Page 4: ...on on waste disposal Proper differentiated collection is necessary so that the obsolete device can be sent on for environmentally friendly recycling treatment and dismantling in order to avoid any pos...

Page 5: ...es Make sure the cabinet in which the blast chiller will be installed is able to support the weight of 40 kg It is necessary to create an opening in the rear part of the bottom of the cabinet or in th...

Page 6: ...corresponding load with opening for each contact of at least 3 mm in accordance with the current local regulations The connection socket must be easily accessible The electrical connection must be do...

Page 7: ...TION key START STOP key CONFIRM key MODELS AI 45BT LX12 TCR INOX AI 45BT LX12 TCW INOX TWO KNOB ASSISTED TOUCH CONTROL PANEL ON OFF key FISH SANIFICATION CYCLE key PRECOOLING CYCLE key BOTTLE CHILLING...

Page 8: ...mains the clock is as shown in the figure with the hours flashing To set the time in the version with knobs turn the knob until you see the desired value and press the key to confirm Perform the same...

Page 9: ...icon POSITIVE 3 C SOFT BLAST CHILL CYCLE WITH NEEDLE PROBE P01 For delicate and thin products POSITIVE 3 C HARD BLAST CHILL CYCLE WITH NEEDLE PROBE P02 For products with a high fat content or large p...

Page 10: ...mis ice cream cake 18 C TIMED HARD DEEP FREEZE CYCLE 200 MINUTES P17 For Raw fish tomato sauce beans 18 C TIMED HARD DEEP FREEZE CYCLE 240 MINUTES P18 For Meat sauce barbecued meat 18 C TIMED HARD CON...

Page 11: ...Default Min Max Default Min Max U06 Set Chamber Temp 3 C 10 C 0 C Set time min 60 10 120 POSITIVE 3 C TIMED HARD BLAST CHILL CYCLE Default Min Max Default Min Max U07 Set Chamber Temp 3 C 10 C 0 C Set...

Page 12: ...t Chamber Temperature Set Probe Temperature Set Time CHECK NEEDLE PROBE INSERTION The unit has a needle probe insertion check This function seeks to determine whether or not the needle probe was inser...

Page 13: ...This decontamination treatment makes seafood products biologically safe and protects the consumer from any toxic infection caused by bacterial contamination and or sea parasites life the Anisakis bact...

Page 14: ...tion They can be activated individually or together Turn the knob until the desired icon is flashing then press and turn it to select the time desired and press once more to confirm The selected icon...

Page 15: ...be must be cleaned before each new cycle in order to avoid contamination LIDS AND CONTAINERS Do not cover the trays and or containers with lids or insulating films The more contact the surface of the...

Page 16: ...nything else that could compromise the quality of the food products The machine must be cleaned with degreasing and disinfectant products used in the kitchen and not using steel wool abrasive sponges...

Page 17: ...r operates but the machine does not cool No freon Call a technician The product size is too large or the trays are not set correctly Remove the product to not exceed the recommended weight It takes a...

Page 18: ...ENGLISH ENGLISH ENGLISH ENGLISH 18 9880028100 EN 240314 WIRING DIAGRAM...

Page 19: ...ENGLISH ENGLISH ENGLISH ENGLISH 19 9880028100 EN 240314 NOTES...

Page 20: ...ENGLISH ENGLISH ENGLISH ENGLISH AI 45BT ENG REV 03 03 2014 9880031700 IT EN 050314...

Reviews: