General information
SMA
Technologie AG
Page 56
WB11_17-11:FE4205
Operating instructions
I-NiTest
mA
0 ... 8000
8000
Activation (8000) and deactivation (0)
of the automatic leakage current
measurement. This parameter only
functions when the Windy Boy is
deactivated (disconnected on the AC
side) or in "Stop" mode.
Inst.-Code
Parameters for mains grid monitoring
can only be changed after entering the
"SMA grid guard" password.
KI-Wind-Reg
0 ... 0,25
0,005
Control speed (only possible in Turbine
mode!)
KP-Wind-Reg
0 ... 0,25
0,117
Control speed (only possible in Turbine
mode!)
P-Wind-Ramp
W/s
10
...
2000
200/280 Slow startup during mains-grid
connection (only possible in Turbine
mode!)
Speicher--
funktion /
Memory
function
Default,
parameter,
Reset
Betriebsdaten,
Reset Fehler
none
Default parameter: Returns all
parameter values to the factory setting.
Reset Betriebsdaten: Returns all user
level parameter values to the factory
setting.
Reset Fehler: Resets a permanent fault.
Speicher(n) /
Store /
Storage
Permanent
volatile
Permanent
Permanent: Modified parameters are
stored in the EEPROM and can be used
even when the Windy Boy has been
restarted.
Volatile: Prevents the parameters from
being stored in the EEPROM, the
parameters are stored until the next
restart.
T-Start
sec
5
...
300
10
Start timer for mains-grid
synchronization. (only possible in
Turbine mode!)
T-Stop
sec
1 ... 3600
2
Stop timer for stopping operation and
switching off. (only possible in Turbine
mode!)
Uac-Min /
Vac-Min
V
180 ... 300
198
Lower (Uac-Min) and upper (Uac-Max)
limits of the acceptable AC voltage (self
contained power system recognition).
Uac-Max /
Vac-Max
V
180 ... 300
260
U
DC
WindMax
V
1 ... 800
330
U
DC
WindMax represents the highest
point of the function (please read more
about this topic in chapter 5 "Turbine
operation” (page 31)). (only possible
in Turbine mode!)
U
DC
WindStart
V
1 ... 800
190
U
DC
WindStart represents the lowest
point of the function (please read more
about this topic in chapter 5 "Turbine
operation” (page 31)). (only possible
in Turbine mode!)
Name
Unit
Value range
(WB 1100 /
WB 1700)
Factory
settings
(WB 1100 /
WB 1700)
Description
Summary of Contents for Windy Boy 1100
Page 2: ......
Page 4: ...SMA Technologie AG Page 4 WB11_17 11 FE4205 Operating Instructions...
Page 12: ...Safety Information SMA Technologie AG Page 12 WB11_17 11 FE4205 Operating instructions...
Page 36: ...Turbine operation SMA Technologie AG Page 36 WB11_17 11 FE4205 Operating instructions...
Page 38: ...Maintenance and care SMA Technologie AG Page 38 WB11_17 11 FE4205 Operating instructions...
Page 64: ...Stand alone systems SMA Technologie AG Page 64 WB11_17 11 FE4205 Operating instructions...
Page 66: ...Contact SMA Technologie AG Page 66 WB11_17 11 FE4205 Operating instructions...
Page 67: ......