SMA Solar Technology AG

LED signals

User Manual

SMC46-60A-BA-BEN114230

15

Green LED 
flashing

This blinking can be caused by:

• The inverter is monitoring the power distribution grid 

and is waiting for the DC voltage to reach a defined 
limit so that it can begin feeding the grid.

• Operation interrupted.
• Power limitation in the inverter.

Red LED on

A ground fault has occurred or one of the thermally 
monitored varistors on the DC input side is defective. 
Inform your installer.

Yellow LED on The inverter is in the operating state "Dauerhafte 

Betriebshemmung" (Permanent Shutdown). 
This can have several causes. Inform your installer.

Yellow LED 
flashing

The inverter displays a disturbance. 
This can have several causes. Inform your installer.

Status

Description

Summary of Contents for SUNNY MINI CENTRAL 4600A

Page 1: ...SMC46 60A BA BEN114230 TBEN SMC46 60A Version 3 0 EN PV inverter SUNNY MINI CENTRAL 4600A 5000A 6000A User Manual...

Page 2: ......

Page 3: ...Safety Instructions 8 2 3 Explanation of Symbols 9 2 3 1 Symbols on the Inverter 9 2 3 2 Symbols on the Type Label 10 3 Product Overview 11 4 Display 12 4 1 Operation 12 4 2 Display Messages during O...

Page 4: ...Table of Contents SMA Solar Technology AG 4 SMC46 60A BA BEN114230 User Manual...

Page 5: ...000A SMC 4600A 11 SMC 5000A 11 SMC 6000A 11 SMC 5000A IT SMC 6000A IT 1 2 Target group This manual is for the operator 1 3 Additional Information You will find additional information on the device spe...

Page 6: ...ed will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation w...

Page 7: ...nd cabling of protection class II Do not connect any energy sources other than PV modules to the Sunny Mini Central Do not use the Sunny Mini Central for purposes other than those described here Alter...

Page 8: ...d only be carried out by a trained electrically skilled person Electrical installation Repair Modification CAUTION Risk of burns through contact with the enclosure during operation Only touch the encl...

Page 9: ...ective Inform your installer An error has occurred Inform your installer immediately You can operate the display by tapping the enclosure lid Tapping once The background light switches on or the displ...

Page 10: ...entation that accompanies the inverter The inverter must not be disposed of together with the household waste Further disposal information can be found in the enclosed installation manual CE mark The...

Page 11: ...EN114230 11 3 Product Overview Position Designation A Display B Enclosure lid C LEDs Green LED Operation Red LED Ground fault or varistor defective Yellow LED Fault D Ventilation grid E Type label for...

Page 12: ...ting one after the other and the configuration of the SMA Power Balancer 4 2 Display Messages during Operation After commissioning the inverter displays the device type the firmware version the config...

Page 13: ...Status message MPP Current feed in power Voltage of the PV array After a further 5 seconds or after tapping the actual values of the reactive power Qac and of the displacement power factor cos PF are...

Page 14: ...LED signals Status Description All LEDs are on The inverter is initializing All LEDs are off The DC input voltage at the inverter is too low for feed in All LEDs flashing The inverter is in the start...

Page 15: ...id Operation interrupted Power limitation in the inverter Red LED on A ground fault has occurred or one of the thermally monitored varistors on the DC input side is defective Inform your installer Yel...

Page 16: ...ct your installer if you find any damage Do not perform any repair work yourself Maintenance and cleaning Ask your installer to check for correct inverter operation at regular intervals If the inverte...

Page 17: ...form your installer MPP The inverter is operating in MPP mode MPP is the standard display message when operating under normal radiation conditions MPP Peak The inverter is operating in MPP mode above...

Page 18: ...of events that have occurred Fac Power frequency Error Identification of the actual disturbance error h On Total operating hours h total Total number of operating hours in feed in operation Iac Grid c...

Page 19: ...of the MPP changes constantly depending on the level of radiation and cell temperature PV Abbreviation for photovoltaics SMA Power Balancer The SMA Power Balancer is a serial feature of the Sunny Min...

Page 20: ...with the necessary assistance Inverter device type inverter serial number Type and number of connected PV modules Blink code or display message of the inverter Optional equipment e g communication pr...

Page 21: ......

Page 22: ......

Page 23: ...product under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring devices beyond sta...

Page 24: ...USBMJB 1UZ UE XXX 4 VTUSBMJB DPN BV 4 FOFMVY 413 XXX 4 FOFMVY DPN 4 FJKJOH PNNFSDJBM P UE XXX 4 IJOB DPN 4 FDI 3FQVCMJD T S P XXX 4 FDI DPN 4 SBODF 4 4 XXX 4 SBODF DPN 4 FMMBT XXX 4 FMMBT DPN 4 C SJDB...

Reviews: