3.2.1 Installation Conditions
Parameter
Specification
Operational temperature range
−
25 °C – +60 °C (possible power derating above 45 °C) (
−
13 °F – 140 °F) (possible power
derating above 113 °F)
Storage temperature
−
40 °C – +60 °C (
−
40°F – 140 °F)
Relative humidity
95% (non-condensing)
Environmental class according to IEC
60721-3-4
4K4H/4Z4/4B2/4S3/4M2/4C2
Cooling concept
Forced
Air quality - general
ISA S71.04-1985
Level G3 (at 75% RH)
Air quality - coastal, heavy industrial and
agricultural zones
Must be measured and classified acc. to ISA S71.04-1985: G3 (at 75% RH)
Vibration
1G
Enclosure rating ingress protection class
IP65
UL 50E enclosure type
Type 3R
Max. operating altitude
2000 m (6500 ft) above sea level (derating may occur at an altitude over 1000 m).
Installation
Avoid constant stream of water.
Avoid direct sunlight.
Ensure adequate air flow.
Mount on non-flammable surface.
Mount upright on vertical surface.
Prevent dust and ammonia gases.
Table 3.1 Conditions for Installation
Parameter
Condition
Specification
Mounting plate
Hole diameter
30 x 9 mm
Alignment
Perpendicular
±
10° all angles
Table 3.2 Mounting Plate Specifications