8 Decommissioning
SMA Solar Technology AG
Installation Manual
MDSEN-US-40-IA-en-13
30
• Press the right or left locking tab of the
communication assembly slightly outwards and
pull the module slightly forwards holding the
lower end until the module is released from the
interlock of the locking tab.
1
2
• Grab the module by the upper and lower edge with one hand.
• Slightly press the second locking tab outwards
using the other hand and pull the module
slightly forwards on the lower end until the
module is released from the interlock of the
locking tab.
1
2
• Remove the module from its slot by pulling it forwards.
6. Remove the conduit and the connection cables from the inverter.
7. Close the inverter and, if necessary, recommission it (see inverter manual).
8.2
Packing the Product for Shipment
• Pack the product for shipping. Use the original packaging or packaging that is suitable for the
weight and size of the product.
8.3
Disposing of the Product
• Dispose of the product in accordance with the locally applicable disposal regulations for
electronic waste.