background image

Accessories for stand-alone grid inverter

BATFUSE

  

Technical Description

BATFUSE-TEN082310 | 98-2004410 | Version 1.0

EN

Summary of Contents for BatFuse A.01-0

Page 1: ...Accessories for stand alone grid inverter BATFUSE Technical Description BATFUSE TEN082310 98 2004410 Version 1 0 EN...

Page 2: ......

Page 3: ...Instructions 7 2 1 Intended Use 7 2 2 General Safety Notices 8 3 Unpacking 9 3 1 Packing List 9 3 2 Check for Transport Damage 10 3 3 Identification of the BatFuse 11 4 Mounting 13 4 1 Dimensions 13...

Page 4: ...ction 19 5 1 BatFuse A 01 and BatFuse A 03 20 5 2 BatFuse B 01 and BatFuse B 03 22 5 3 Using or Replacing NH Fuses 24 5 3 1 BatFuse A 01 and BatFuse A 03 25 5 3 2 BatFuse B 01 and BatFuse B 03 26 6 Op...

Page 5: ...l Sunny Islands BatFuse as it appears in this manual refers to all four models 1 1 Validity These technical instructions are valid for the installation and start up of BatFuse models BatFuse A 01 BatF...

Page 6: ...sages are used in this document DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not a...

Page 7: ...onnection of up to three Sunny Islands BatFuse A 01 0 Battery connection box for a Sunny Island 2224 with fuse plug 125 A BatFuse B 01 0 Battery connection box for a Sunny Island 2224 with load discon...

Page 8: ...NGER Risk of lethal electric shock Only qualified personnel are permitted to install the electical connections Observe sufficient cable cross section and correct polarity of the cables Insert NH fuses...

Page 9: ...ounting plates 2 Replacement fuses NH00 125 A 1 installation guide 1 BatFuse A 03 DC fuse box 4 Wall mounting plates 2 Replacement fuses NH00 125 A 1 installation guide 1 BatFuse B 01 DC fuse box 4 Wa...

Page 10: ...eck the packaging and the BatFuse for any signs of damage Ensure that all parts are included in the delivery see section 3 1 Packing List Page 9 If something is missing or if the BatFuse was damaged d...

Page 11: ...AG Unpacking Technical Description BATFUSE TEN082310 Page 11 3 3 Identification of the BatFuse You can identify the DC fuse through the type label The type label can be found inside the housing BatFu...

Page 12: ...01 BatFuse B 03 The nominal current strength I nom and voltage V nom are dependent upon the utilized Sunny Island V nom lies in the range 12 48 V I nom in the range 125 250 A See table For the connec...

Page 13: ...SMA Solar Technology AG Mounting Technical Description BATFUSE TEN082310 Page 13 4 Mounting 4 1 Dimensions 4 1 1 BatFuse A 01 4 1 2 BatFuse A 03...

Page 14: ...Mounting SMA Solar Technology AG Page 14 BATFUSE TEN082310 Technical Description 4 1 3 BatFuse B 01 4 1 4 BatFuse B 03...

Page 15: ...um clearances Observe the following minimum clearances when mounting the BatFuse These apply to all housing types 4 3 Wall Mounting WARNING Fire and explosion hazard Do not mount the BatFuse on flamma...

Page 16: ...Technical Description 4 3 1 BatFuse A 01 and BatFuse A 03 Mount the BatFuse on the wall Proceed as follows 1 Remove the lid 2 There are two options for aligning the mounting plates see the following...

Page 17: ...nting Technical Description BATFUSE TEN082310 Page 17 BatFuse A 03 3 Insert wall mounting plates 4 Mark drill holes on the wall 5 Drill holes and insert wall anchors 6 Fasten housing on the wall 370 m...

Page 18: ...Fuse B 01 and BatFuse B 03 Mount the BatFuse on the wall Proceed as follows 1 There are three options for aligning the mounting plates see the following illustrations 2 Mark drill holes on the wall 3...

Page 19: ...e the instructions in the section Switching On and Off in the technical instructions of the Sunny Island Information The battery cable should be as short as possible Long cables and insufficient cable...

Page 20: ...t and strip the battery cables as well as the charge controller cables BatFuse A 01 BatFuse A 03 Maximum number of terminals Battery side 2 x M32 per pin 2 x M32 and 2 x M25 per pin Maximum number of...

Page 21: ...ds 7 Connect the Sunny Island to the top side of the BatFuse and the battery and charge controller to the bottom side Screw the pipe cable lugs to the appropriate connection terminal and tighten each...

Page 22: ...ection unit from the bracket and store it in a safe place for the duration of the installation 4 Pierce the outer membrane of the required double membrane adapter with a sharp tool BatFuse B 01 BatFus...

Page 23: ...t potential consumers to the battery voltage tap 6 Cut and strip the battery cables as well as the charge controller cables 7 Guide the cables into the housing through the double membrane adapters 8 A...

Page 24: ...arcs Only after completing all installation and maintenance work in the system you should insert the NH fuses or close the load disconnection unit NH fuses must not be inserted or pulled under load Se...

Page 25: ...nd BatFuse A 03 Inserting 1 First place the bottom of the NH fuse on the bracket using the NH handle as per VDE 0680 4 2 Subsequently quickly press the NH fuse into the bracket 3 Put the lid on and lo...

Page 26: ...ing the NH handle as per VDE 0680 4 2 Remove the defective NH fuse 3 Insert the new NH fuse see Inserting Page 25 4 Put the lid on and lock it 5 3 2 BatFuse B 01 and BatFuse B 03 Inserting 1 First pla...

Page 27: ...Technical Description BATFUSE TEN082310 Page 27 Replacement 1 Press the NH fuse downwards Then pull the NH fuse from the bracket 2 Remove the defective NH fuse 3 Insert the new NH fuse see Inserting...

Page 28: ...for the duration of the task 6 2 Closing the BatFuse 1 Check whether all cables are safely installed and that all tools were removed from the inside of the BatFuse 2 Put the lid on 3 Tighten the lid...

Page 29: ...Weight 1 5 kg 3 8 kg BatFuse B 01 BatFuse B 03 Output values Nominal DC voltage Sunny Island 2012 12 V 12 V Sunny Island 2224 Sunny Island 3324 24 V 24 V Sunny Island 4248 Sunny Island 5048 48 V 48 V...

Page 30: ...ur products contact the SMA Service Line We require the following information in order to provide you with the necessary assistance BatFuse serial number Connected inverters Connected battery SMA Sola...

Page 31: ...s and instructions contained in all documents relevant to the product Operating the product under incorrect safety or protection conditions Altering the product or supplied software without authority...

Page 32: ...SMA Solar Technology AG www SMA de Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 4000 Fax 49 561 9522 4040 E Mail Vertrieb SMA de Freecall 0800 SUNNYBOY Freecall 0800 78669269...