62
7.2
LOOPS
To control the equipment correct operation a set of local and remote loops are made available. The com-
mands are forwarded by the WEBLCT program. The available loop facilities are:
•
Line Loop (Ethernet Port Loop)
•
Baseband loop
•
RF loop (only for GB8xxxx)
Fig.19 - Available loops
7.3
RATE LIMITING AND INGRESS FILTER POLICING
7.3.1
Rate limiting
In SIAE equipment it is possible to apply the Rate Limit, i.e. to limit the total rate passing through an in-
terface. It is possible to apply the rate limiting from 64 kbit/s up to the maximum port speed (up to 1GE).
The values that can be inserted are pre-fixed from 64 kbit up to 10Mbit (64Kb, 128kb, 256kb, 512kb, 1Mb,
2Mb, 3Mb, 4Mb, 5Mb, 6Mb, 7Mb, 8Mb and 9Mb), In the range from 10Mbit/s up to 1Gbit/s the limiting val-
ues can be chosen by the user with a 10Mbit/s step. i.e. the minimum selectable granularity is 10Mb/s.
7.3.2
Ingress filtering policy (CIR/EIR according to MEF 10.2)
SIAE equipment allows limiting the ingress traffic rate on the basis of:
•
LAN port (Bandwidth profile per UNI): a different profile is defined for each LAN port (VLAN ID and
priority are not considered in this case by the rate limiting algorithm)
•
VLAN (Bandwidth profile per EVC): a different profile is defined for different VLANs (priority is not
considered in this case by the rate limiting algorithm). Up to 64 VLAN can be managed with different
profiles.
•
VLAN + priority (Bandwidth profile per CoS): a different profile is defined for different couples
VLAN+priorities (up to 64 different cases can be managed). In this case the packet priority is always
considered by the rate limiting algorithm. More than one priority can be included in the same band-
width profile.
ALFO Plus
BBP-GE
RADIO
RF Loop
BASE
BAND
LOOP
Tx
LINE
LOOP
Rx
PHYSICAL
ETHERNET
PORT
Summary of Contents for ALFOplus
Page 1: ...ALFOplus Access Link Full Outdoor User Manual MN 00273 E 004 ...
Page 16: ...14 MN 00273 E 004 ...
Page 22: ...20 MN 00273 E 004 Fig 6 ALFOplus front side view 254 mm 254 mm 157 mm ...
Page 86: ...84 MN 00273 E 004 ...
Page 97: ...MN 00273 E 004 95 Fig 34 ODU with standard coupling kit O ring Coupling kit ...
Page 98: ...96 MN 00273 E 004 Fig 35 1 0 ODU installation 3 1 2 ...
Page 99: ...MN 00273 E 004 97 Fig 36 Polarization disk Reference ...
Page 100: ...98 MN 00273 E 004 Fig 37 1 1 ODU installation 3 1 2 ...
Page 101: ...MN 00273 E 004 99 Fig 38 1 0 antenna flange 4 3 4 1 2 5 114 60 ...
Page 102: ...100 MN 00273 E 004 Fig 39 1 1 antenna flange 3 1 2 4 7 5 6 ...
Page 109: ...MN 00273 E 004 107 Fig 49 Bend strain relief to lay along cable Crimp plug and strain relief ...
Page 112: ...110 MN 00273 E 004 Fig 53 PO0032 ...
Page 118: ...116 MN 00273 E 004 Fig 58 ALFOplus connectors Fig 59 SFP LC LC Fig 60 SFP LC OPEN END ...
Page 119: ...MN 00273 E 004 117 Fig 61 SFP LC SFP LC Fig 62 LC connector Fig 63 SFP into ALFOplus ...
Page 120: ...118 MN 00273 E 004 Fig 64 Locked connection Fig 65 Unplug SFP ...
Page 123: ...MN 00273 E 004 121 Fig 66 IP address setting Fig 67 Local area connection ...
Page 144: ...142 MN 00273 E 004 Fig 82 Event log window ...
Page 150: ...148 MN 00273 E 004 ...
Page 220: ...218 MN 00273 E 004 ...
Page 224: ...222 MN 00273 E 004 ...
Page 230: ...228 MN 00273 E 004 ...