6. 

Indicator light installation:

 Feed cable of 

indicator light through cutout and into switch 

outlet box. Secure cable using included 

strain relief connector. Ensure drywall 

anchors are retracted far enough that wings 

will be able to pop open by turning screws 

counter-clockwise until anchor is at end of 

bolt. Insert light into cutout and turn bolts 

clockwise until anchors are securely held 

against back of drywall. Connect indicator 

light to wireless receiver via connectors.

1. 

Mount sensor in main area of restroom that will 

experience most traffic. Sensor should be mounted

 

6 - 8 ft (1.8 - 2.4 m) from ground.

2. 

Remove mounting plate from sensor by pressing release 

tab located on top of sensor. Hold mounting plate against 

wall and mark two (2) mounting points. Drill two holes 

with a 0.1875" (4.8 mm) bit and insert wall anchors.

 

Insert first screw loosely and level mounting plate.

 

Insert second screw and hand-tighten both screws.

3. 

System operation and setup: 

System has been 

programmed and sensors have been linked to the 

corresponding receivers. No setup is required. When 

sensor detects motion, indicator light will be illuminated 

RED. If no motion is detected for 45 seconds, light will 

change to GREEN.

Wireless sensor Installation – Wall mount

1. 

Remove mounting plate from sensor. Hold mounting plate 

in place on ceiling and use a pencil to lightly mark two (2) 

small dots for screw drill points. Drill two (2) holes with a 

0.1875" (4.8 mm) drill bit and insert wall anchors. Insert 

first screw loosely and level mounting plate. Insert second 

screw and hand-tighten both screws.

2. 

Remove  ceiling  tile  from  desired  installation  location. 

Place mounting plate squarely on ceiling tile and insert 

wire  bracket  through  two  (2)  holes  in  mounting  plate. 

Feed wires through holes in ceiling tile. On front of ceiling 

tile, flatten wire bracket so it is snug against mounting 

plate. On back of ceiling tile, twist wires together to hold 

mounting plate securely.

3. 

Attach sensor to mounting plate, sliding sensor onto 

mounting plate until it snaps into place.

Wireless sensor Installation – Ceiling mount

Touchless Occupancy Indicator System

Installation Guide for 601146, 601147, 601148, and 601153

PAGE 2 OF 3