background image

Repair Parts and Maintenance Guide

The information contained in this document is subject to change without notice.

TruFlush Hardwired/Battery 

Flushometers

Code No.

Part No.

Description

34001003

TRF 

8036

TRF8036 Dual Flush 3/6 LPF Valve 

VALVE ASSEMBLY SELECTION GUIDE          

Filter Screen

Code No. Part No.

Description

Piston Color*

03400054

-

GBL Piston Assy-ELE Dual Flush

Orange

 & Red

PISTON PARTS LIST SELECTION GUIDE          

Code No. Part No.

Description

Aspirator Retainer Color*

03400056

-

GBL Elect ACT ASM-Dual Flush

Orange

 & Red

ACTIVATION ASSEMBLY SELECTION GUIDE

ASPIRATOR ASSEMBLY SELECTION GUIDE

Code No. Part No.

Description

Aspirator Retainer Color*

0340211

GBL142-6

GBL142-6 Retainer Umbrella C/V Orange

Orange

0340199

GBL142-4

GBL142-4 Retainer umbrella C/V Orange

)

Red

$&7,9$7,21$66(0%/<5(3$,5.,7

3,6721$66(0%/<5(3$,5.,7

1.

BATTERY REPLACEM

ENT

-

-

+

+

+

-

H.

Reinstall the Battery cover and using a screwdriver tighten the screw until the battery cover is tightly secure.

I.

Follow section 3,4,5 and 7 of this installation guide to complete installation.

When required, replace batteries with four (4) Alkaline AA-Size Batteries.

NOTE: WATER DOES NOT HAVE TO BE TURNED OFF TO REPLACE BATTERIES. USE ALKALINE BATTERIES FOR PROPER UNIT 
OPERATION.

A.

Remove Wall Plate

B.

Disconnect solenoid from 

pcb

 assembly. Pull on end connector to prevent damage to wires.

C.

Slide 

pcb

 Assembly all the way up and remove from wall bracket

D.

Disconnect power from 

pcb

 Assembly

E.

Remove battery box from inside the Wall Box

F.

Remove the battery box cover by loosening screw using a Philips head screwdriver.

G.

Replace the batteries with 4 new AA Alkaline batteries as shown.

2

Reviews: