background image

PARTS LIST

2A

2B

2C

Item # Part # 

Description

EAF-14-A  Faucet Sensor Assembly (EAF-275 only)

 

EAF-19-A  Faucet Sensor Assembly (EAF-200 and EAF-225 only)

 

EAF-21-A  Faucet Sensor Assembly (EAF-250 only)

 

EAF-16-A  Faucet Sensor Assembly with i.q.-Click (EAF-275 only)

 

EAF-18-A  Faucet Sensor Assembly with i.q.-Click (EAF-200 and  

 

 

EAF-225 only)

 

EAF-20-A  Faucet Sensor Assembly with i.q.-Click (EAF-250 only)

2A 

EAF-1006  Cap with Solar Cell Assembly (EAF-275 only)

2B 

EAF-27 

Cap (EAF-250 and EAF-200 only)

2C 

— 

Cap (EAF-225)

3A 

EAF-12 

0.5 gpm (1.9 Lpm) VR Pressure Compensating Spray Head

3B 

EAF-22 

1.5 gpm (5.6 Lpm) Pressure Compensating Aerated  

  

Stream 

3C 

EAF-10 

2.2 gpm (8.3 Lpm) Aerator Spray Head

3D 

EAF-13 

2.2 gpm (8.3 Lpm) Laminar Flow Spray Head

EAF-1003  Battery Replacement Kit

EAF-1 

Faucet Mounting Kit

EAF-9 

Strainer (Filter)

7A 

EAF-1004  Mixer Handle Assembly and Cartridge

7B 

EAF-1005  Handle Repair Kit

EAF-1007  Handle Cap

EAF-1008  13” (330 mm) Flexible Supply Hose

10 

EAF-44 

Power Splitter†

11 

EAF-24-A  11-13/16” (300 mm) Extension Cable

 

EAF-25-A  47-1/4” (1200 mm) Extension Cable

 

EAF-17-A  126” (3200 mm) Extension Cable

12 

ETF-312-A  Trim Plate for 4” Centerset Sink

13 

ETF-510-A  Trim Plate for 8” Centerset Sink

14 

EAF-11 

Plug-in Adapter (Models EAF-200/225)

15 

EAF-2

 Solenoid

† EAF-44 replaces the separate EAF-23-A Splitter Cable and EAF-28 

Capacitor, which is sold separately.

3A

3B

3C

3D

7A

7B

4

1

5

13

9

12

6

8

14

The information contained in this document is subject to change without notice.

SLOAN • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131

Phone: 1-800-982-5839 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • www.sloan.com

© 2016 SLOAN  

   

 

Code No: 0816490 – Rev. 6 (05/16)

11

10

15

1. Problem:  Faucet does not function.

  Cause: 

Adhesive packaging label affixed over sensor eye.

  Solution:  Remove adhesive label from sensor eye.

  Cause: 

“Permanent Off” activated.

  Solution:  Press button on faucet throat one time.

2. Problem:  Faucet delivers water in an uncontrolled manner.

  Cause: 

Faucet is defective.

  Solution:  Contact the Sloan Technical Support (see below).

3. Problem:  Faucet does not deliver any water when Sensor is 

 activated.

  Indicator:  Solenoid valve produces an audible “CLICK.”

  Cause: 

Water supply stop(s) closed.

  Solution:  Open water supply stop(s).

  Cause: 

Water supply stop strainer(s) clogged.

  Solution:  Remove, clean, and reinstall water supply stop strainer(s).

Replace strainer(s) if required.

 

Indicator:  Solenoid valve DOES NOT produce an audible “CLICK.”

  Cause: 

Battery low (battery-powered models).

  Solution:  Replace battery (refer to Battery Replacement on Page 3).

  Cause: 

Power failure (EAF-200 Models).

  Solution:  Check power supply.

4. Problem:  Faucet delivers only a slow flow or dribble when Sensor 

 

is activated.

  Cause: 

Water supply stop(s) are partially closed.

  Solution:  Completely open water supply stop(s).

  Cause: 

Water supply stop strainer(s) clogged.

  Solution:  Remove, clean, and reinstall water supply stop strainer(s). 

Replace strainer(s) if required.

4. Problem:  Faucet delivers only a slow flow or dribble when Sensor 

 

is activated.

  Cause: 

Aerator is clogged.

  Solution:  Remove, clean, and reinstall aerator. Replace aerator if 

required.

  Cause: 

Faucet is defective.

  Solution:  Contact the Sloan Technical Support (see below).

5. Problem:  Faucet does not stop delivering water or continues to 

 

drip after user is no longer detected.

  Cause: 

Valve is defective.

  Solution:  Contact the Sloan Technical Support (see below).

6. Problem:  LED indicator blinks when faucet is in use.

  Cause: 

Battery low (battery-powered models).

  Solution:  Replace battery (refer to Battery Replacement on Page 3).

7. Problem:  The water temperature is too hot or too cold on a faucet 

 

connected to hot and cold supply lines.

  Cause: 

Supply Stops are not adjusted properly.

  Solution:  Adjust Supply Stops.

  Cause: 

For models with integral mixing valve — Mixing valve is set 

improperly for the water temperature desired.

  Solution:  Rotate mixing valve handle clockwise to decrease water 

temperature or counterclockwise to increase water 

temperature.

When assistance is required, please contact Sloan Technical Support at:

1-888-SLOAN-14 (1-888-756-2614)

TROUBLESHOOTING GUIDE

Summary of Contents for Solis EAF-275 Series

Page 1: ...330 mm LONG FLEX HOSE MIXING LEVER Can Be Set and Removed TEMPERED SUPPLY SPOUT O RING 1 3 16 30 mm MIN DIA HOLE REQUIRED GASKET RETAINER NUT 13 330 mm LONG FLEX HOSE 1 1 2 38 mm MAX DECK THICKNESS I...

Page 2: ...r and Flex Hose onto Supply Stop B Tighten the Flex Hose with Strainer in place securely to the Supply IMPORTANT Flush dirt debris and sediment from supply line s before Connecting Flex Hoses SUPPLY L...

Page 3: ...y Stop s NOTE Replace Battery when red LED indicator flashes each time faucet is in use or when faucet stops functioning 3 D Insert a new 6 Volt Type CR P2 Lithium Battery The red LED will flash for o...

Page 4: ...emove cover BLUE Cold End Position RED HOT End Position Tempered Position B Press button for approximately 5 seconds C When illuminant glows PURPLE release E Press button once F Replace top cover 1 D...

Page 5: ...ess button twice and release C Illuminant flashes red D Adjust mixing lever for position RED hot and press button once E Illuminant flashes F Adjust mixing lever for position temperate and press butto...

Page 6: ...A B C D E F G DISCLAIMER Updated electronics have visible red and green LED Original electronics have only red LED and range setting is reversed 1 longest 8 shortest FACTORY SETTING IS APPROPRIATE FOR...

Page 7: ...range the beam is reflected back into the sensor receiver and activates the solenoid valve allowing water to flow from the faucet Water will flow until the hands are removed or until the faucet reach...

Page 8: ...uncontrolled manner Cause Faucet is defective Solution Contact the Sloan Technical Support see below 3 Problem Faucet does not deliver any water when Sensor is activated Indicator Solenoid valve produ...

Reviews: