background image

SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131

Phone: 1-800-982-5839 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380

www.sloanvalve.com

11-08

Copyright © 2008 SLOAN VALVE COMPANY

11

10

9

8

PARTS LIST

1

Item

Part

Description

No.

No.

1

ETF-797-A

Faucet Spout and Sensor Assembly

2A

ETF-687

1.5 gpm/5.7 Lpm Laminar Flow Spray Head

2B

ETF-801

0.5 gpm/1.9 Lpm Aerator Spray Head

3

EL-356

Mounting Plate with Slotted Flat Head Screws (4)

4 †

ETF-530

Compression Fitting

5 †

ETF-61

Compression Fittings (2)

6

ETF-370-A

24 VAC Solenoid Valve Assembly; Includes Wire Harness

7

ETF-617-A

3/8” Bak-Chek

®

Tee Compression Fitting

8

ETF-450-A

Control Module Assembly

9

EL-248-40

Box Mount Transformer

10

ETF-233

Plug-In Transformer

11

ETF-458-A

Power Cable with Strain Relief and Crimp Connectors (Transformer to Control Module)

12

MIX-19

Flex Hose

13

ETF-133

Set Screw

ETF-798-A

Installation Kit, includes (1) ETF-530, (2) ETF-61 Compression Fittings, (4) Mounting Fasteners and (1) Hex Wrench 

SOLENOID VALVE REPAIR KITS

ETF-1009-A

Solenoid Valve Repair Kit, Includes Replacement Filter

If further assistance is required, please contact the Sloan Valve Company Installation Engineering Department at 1-888-SLOAN-14 (1-888-756-2614).

NOTICE: The information contained in this document is subject to change without notice.

2A

3

4

5

5

6

7

12

2B

13

Summary of Contents for Optima ETF-800

Page 1: ......

Page 2: ...FAUCET WALL PLATE ASSEMBLY SET SCREW MOUNTING PLATE WALL PLASTER RING SENSOR CABLE FLEX HOSE ELECTRICAL BOX 4 X 4 1 Determine Mounting Location and Cut Mounting Hole A Measure and mark mounting hole l...

Page 3: ...to Faucet Tighten fitting securely 2 Install Electrical Box and Mounting Plate to Wall A Position and hold Electrical Box with Plaster Ring behind wall Fasten Mounting Plate to Plaster Ring using fou...

Page 4: ...OX MOUNT TRANSFORMER Important DO NOT supply power to primary side of Transformer until wiring is completed Mount Transformer on a metal electrical junction box supplied by others J box should be moun...

Page 5: ...ack A Route Cables from Solenoid Valve and Spout to the Control Module 11 Plug In Transformer A Plug Transformer into 120 VAC Receptacle Start Up 10 CONTROL MODULE ENCLOSURE FROM SOLENOID VALVE FROM T...

Page 6: ...desired Time Out The Dip Switches used to set the Time Out are located in the Control Module Set the Time Out by configuring the number 1 2 and 3 Dip Switches as shown in Table 1 Table 1 Time Out Set...

Page 7: ...d LED in upper left corner of circuit does NOT illuminate CAUSE Sensor range is set too long and is detecting the sink SOLUTION Reduce Sensor detection range CAUSE Sensor is faulty SOLUTION Replace Se...

Page 8: ...es Wire Harness 7 ETF 617 A 3 8 Bak Chek Tee Compression Fitting 8 ETF 450 A Control Module Assembly 9 EL 248 40 Box Mount Transformer 10 ETF 233 Plug In Transformer 11 ETF 458 A Power Cable with Stra...

Reviews: