background image

EBF-615 FAUCET ROUGH-IN — Figure A

EBF-650 FAUCET ROUGH-IN — Figure B

SPOUT

WING NUT AND
SLOTTED WASHER

1/8" NPT PIPE TO 3/8" TUBE
COMPRESSION FITTING

3/8" COMPRESSION STOPS (NOT SUPPLIED)

BACK CHECK
(HOT SUPPLY)

1/8" PIPE NIPPLE

BACK CHECK

(COLD SUPPLY)

3/8" COMPRESSION TEE

3/8" COMPRESSION
FITTING

3/8" COMPRESSION FITTING

3/8" COPPER SUPPLY

TUBE (NOT SUPPLIED)

CONTROL MODULE

3/8" COPPER SUPPLY
TUBE (NOT SUPPLIED)

3/8" COPPER
SUPPLY TUBES
(NOT SUPPLIED)

SOLENOID VALVE

BASE GASKET

EBF-650 FAUCET WITH DUAL LINE WATER SUPPLY

MODEL EBF-650-A-2 — 0.5 gpm (1.9 Lpm) Max.
MODEL EBF-650-B-2 — 2.2 gpm (8.3 Lpm) Max.
MODEL EBF-650-C-2 — 2.2 gpm (8.3 Lpm) Max. Laminar Flow

† 1" (25 mm) minimum diameter hole required to mount faucet shank on deck.

‡ 3/8" (10 mm) minimum diameter clearance for mounting studs.

3/8" COMPRESSION STOP OR

MIXING VALVE (NOT SUPPLIED)

SPOUT

WING NUT AND
SLOTTED WASHER

1/8" NPT PIPE TO 3/8" TUBE
COMPRESSION FITTING

1/8" PIPE NIPPLE

3/8" COMPRESSION
FITTING

3/8" COMPRESSION FITTING

CONTROL MODULE

3/8" COPPER SUPPLY
TUBE (NOT SUPPLIED)

3/8" COPPER
SUPPLY TUBE
(NOT SUPPLIED)

SOLENOID VALVE

BASE GASKET

EBF-650 FAUCET WITH SINGLE LINE WATER SUPPLY

MODEL EBF-650-A — 0.5 gpm (1.9 Lpm) Max.
MODEL EBF-650-B — 2.2 gpm (8.3 Lpm) Max.
MODEL EBF-650-C — 2.2 gpm (8.3 Lpm) Max. Laminar Flow

EBF-615 FAUCET WITH DUAL LINE WATER SUPPLY

MODEL EBF-615-A-2 — 0.5 gpm (1.9 Lpm) Max.
MODEL EBF-615-B-2 — 2.2 gpm (8.3 Lpm) Max.
MODEL EBF-615-C-2 — 2.2 gpm (8.3 Lpm) Max. Laminar Flow

SPOUT

1/4" NPT PIPE TO 3/8" TUBE
COMPRESSION FITTING

3/8" COMPRESSION STOPS (NOT SUPPLIED)

BACK CHECK
(HOT SUPPLY)

SPACER, FLAT WASHER,
LOCK WASHER AND NUT

BACK CHECK

(COLD SUPPLY)

3/8" COMPRESSION TEE

3/8" COMPRESSION
FITTING

3/8" COMPRESSION FITTING

3/8" COPPER SUPPLY

TUBE (NOT SUPPLIED)

CONTROL MODULE

3/8" COPPER SUPPLY
TUBE (NOT SUPPLIED)

3/8" COPPER
SUPPLY TUBES
(NOT SUPPLIED)

SOLENOID VALVE

BASE GASKET

EBF-615 FAUCET WITH SINGLE LINE WATER SUPPLY

MODEL EBF-615-A — 0.5 gpm (1.9 Lpm) Max.
MODEL EBF-615-B — 2.2 gpm (8.3 Lpm) Max.
MODEL EBF-615-C — 2.2 gpm (8.3 Lpm) Max. Laminar Flow

3/8" COMPRESSION STOP OR

MIXING VALVE (NOT SUPPLIED)

SPOUT

WING NUT AND
SLOTTED WASHER

1/4" NPT PIPE TO 3/8" TUBE
COMPRESSION FITTING

SPACER, FLAT WASHER,
LOCK WASHER AND NUT

3/8" COMPRESSION
FITTING

3/8" COMPRESSION FITTING

CONTROL MODULE

3/8" COPPER SUPPLY
TUBE (NOT SUPPLIED)

3/8" COPPER
SUPPLY TUBE
(NOT SUPPLIED)

SOLENOID VALVE

BASE GASKET

2

Summary of Contents for Optima EBF-615

Page 1: ...Department at 1 888 SLOAN 14 EBF 650 I I Rev 1 06 00 Code No 0816321 INSTALLATION INSTRUCTIONS BATTERY POWERED SENSOR OPERATED LAVATORY FAUCETS EBF 615 EBF 650 Battery Powered Sensor Operated Lavator...

Page 2: ...D VALVE BASE GASKET EBF 650 FAUCET WITH SINGLE LINE WATER SUPPLY MODEL EBF 650 A 0 5 gpm 1 9 Lpm Max MODEL EBF 650 B 2 2 gpm 8 3 Lpm Max MODEL EBF 650 C 2 2 gpm 8 3 Lpm Max Laminar Flow EBF 615 FAUCET...

Page 3: ...supply or a pre tempered water supply a back check is not required Step 1 Install Back Checks Option Figure 1 TheSloanBackCheckisdesignedfor installation on a 3 8 Supply Stop If an existingStopisused...

Page 4: ...or B All four 4 Cover Screws must be accessible from the chosenmounting position After installation the Cable from Spout to Control Module should have some slack Remove Control Module Cover from Cont...

Page 5: ...er supply no Back Check is required Install a 3 8 copper Supply Tube between the Supply Stop and the bottom inlet Compression Fitting of Solenoid Valve Refer to Figure A or B Step 7 Install Batteries...

Page 6: ...ustment is required turn Range Potentiometer counterclockwise to decrease range or clockwise to increase range Cycle Faucet several times to assure that the Sensor range does not inadvertentlypickup r...

Page 7: ...tting off the water flow The circuit then automatically resets and is ready for the next user CARE AND CLEANING OF CHROME AND SPECIAL FINISHES DO NOT use abrasive or chemical cleaners including chlori...

Page 8: ...D should flash RED when a user is detected 3 PROBLEM Faucet delivers only a slow flow or dribble when Sensor is activated CAUSE Water supply valve is partially closed SOLUTION Completely open the Supp...

Page 9: ...ter turn off the water supply at the supply stop s Activate the faucet to relieve any pressure in the system Unscrew the Filter Plug and remove it from the Solenoid Valve Housing Carefully pull the Sc...

Page 10: ...ssion Sleeves and Screwdriver Not shown 6 EBF 60 A Control Module Assembly includes Base Enclosure Cover Enclosure two 2 Gaskets Solenoid Body Solenoid Enclosure Solenoid Filter Plug and Battery Stop...