PRIOR TO INSTALLATION

Prior to installing the Sloan Navel Flushometer, install the items listed below as
illustrated in Figure 1.

Closet/urinal fixture

Drain line

Water supply line

Important:

ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.

WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE
VOLUME OF WATER FOR EACH FIXTURE.

FLUSH ALL WATER LINES PRIOR TO INSTALLING FLUSHOMETER

The Sloan Naval

®

is designed to operate with 10 to 100 psi (69 to 689 kPa) of

water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS
DETERMINED BY THE TYPE  OF  FIXTURE SELECTED. Consult  fixture
manufacturer for minimum pressure requirements.

Most Low Consumption water closets (1.6 gallon/6 liter) require a minimum
flowing pressure of 25 psi (172 kPa).

Protect the Chrome or Special finish of this flushometer — DO NOT USE
TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE. Also, see “Care
and Cleaning” section of this manual.

IMPORTANT: WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT
USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE
COMPONENT OR COUPLING!

TOOLS REQUIRED FOR INSTALLATION

Slotted screwdriver

Sloan A-50 “Super-Wrench™” or smooth jawed spud wrench

INSTALLATION

Step 1 - Control Stop Installation (Figure 2)

Install the Sloan Bak-Chek

®

Control Stop and Supply Flange to the water supply

line with the outlet positioned as required.

For Sweat Solder applications, see the following instructions & Figure 3:
A. Measure distance from finished wall to centerline of Fixture Spud. Cut water

supply pipe 1-1/4" (32 mm) shorter than this measurement. Chamfer O.D.
and I.D. of water supply pipe.

B. Slide Threaded Adapter onto water supply pipe until end of pipe rests against

shoulder of Adapter. Sweat solder Adapter to water supply pipe.

C. Determine length of Covering Tube by measuring distance from finished wall

to the first thread of Adapter (dimension “X” in Figure 3). Cut Covering Tube
to this length.

D. Slide Covering Tube onto water supply pipe. Slide Wall Flange over Covering

Tube until it rests against the finished wall.

E. Install the Sloan Bak-Chek

®

Control Stop to the water supply line with the

outlet positioned as required.

Step 2 - Install Vacuum Breaker Flush Connection (Figure 4)

Slide the Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud Flange
over the Vacuum Breaker Tube and insert tube into Fixture Spud. Hand tighten
Spud Coupling onto Fixture Spud.

Note: On valves furnished less vacuum breaker, (XYV variation), connect flush

tube to the bottom of the valve using the slip gasket supplied.

Step 3 - Install Flushometer

SLOAN ADJUSTABLE TAILPIECE (Figure 5)

The Sloan Adjustable Tailpiece compensates for “off-center” roughing-in on the
job. Maximum adjustment is 1/2" (13 mm) IN or 1/2" (13 mm) OUT from the
standard 4-3/4" (121 mm) (centerline of Flushometer to centerline of Control
Stop).

If a ground joint tailpiece has been specified (recommended for seawater
applications), there is no lateral adjustment; therefore, the 4-3/4" (121 mm)

NOTE: If roughing-in measurement
exceeds 5-1/4" (133 mm), a longer
tail may be supplied.

4-1/4"

(108 mm) MIN.

5-1/4"

(133 mm) MAX.

Figure 5

IRON PIPE NIPPLE OR COPPER PIPE
WITH SWEAT SOLDER ADAPTER

SUPPLY
FLANGE

BAK-CHEK

®

CONTROL STOP

STOP CAP

Figure 2

SET
SCREW

COVERING TUBE

“YBYC” VARIATION SHOWN

Figure 4

MODEL 110/111
MODEL 113/115/116
MODEL 117

MODEL 120
MODEL 121
MODEL 122

MODEL 180

MODEL 186

SPUD
COUPLING

VACUUM
BREAKER
TUBE

NYLON
SLIP
GASKET

RUBBER
GASKET

SPUD
FLANGE

SPUD
COUPLING

VACUUM
BREAKER

NYLON
SLIP
GASKET

RUBBER
GASKET

SPUD
FLANGE

VACUUM
BREAKER
TUBE

SPUD
COUPLING

NYLON
SLIP
GASKET

RUBBER
GASKET

SPUD
FLANGE

ELBOW FLUSH
CONNECTION

C/L OF FIXTURE SPUD

ADAPTER

WATER SUPPLY PIPE

WALL FLANGE

COVERING TUBE

1-1/4" (32 mm)

FINISHED WALL

Figure 3

“X”