background image

CONSUMABLES

Product No.

Description

Order No.

SJS-1751

Sensor Deck-Mount Foam Soap

5700751

SJS-1751-1

Sensor Deck-Mount Foam Soap with Moisturizers 

5700752

SJS-1751-3 

Sensor Deck-Mount Foam Soap

 

(Fragrance Free) 

5700754

SJS-1751-4 

Sensor Deck-Mount Foam Soap

 

(Rose)

5700755

EMERGENCY MEASURES

Take action according to the chemical being used
as listed on the container. See the Safety Data
Sheets.

Eye Contact: Flush eyes with water for a
minimum of 15 minutes and consult a physician
immediately.

Ingestion: Drink water to induce vomiting and
consult a physician immediately.

Inhalation: Get fresh air immediately. If condition
does not improve, consult a physician
immediately.

The information contained in this document is 
subject to change without notice.

Sloan Valve Company
10500 Seymour Avenue
Franklin Park, IL 60131-1259
Phone: 877-652-6726
Fax: 800-447-8329
www.sloanvalve.com

©2015 Sloan Valve Company

Code. 0816685

Rev.1 (02/15)

Summary of Contents for ESD-400

Page 1: ...400 Sensor Operated Deck Mount Foam Soap Dispenser Specifications Width 1 747 44 37 mm Height 4 40 118 mm Depth 4 50 114 3 mm Dispenser Rate Approximately 1 2 mL per use Capacity 1000 mL bottle Speci...

Page 2: ...1 8 mm 9 25 235 mm 2 25 57 mm 7 87 200 mm 4 50 114 3 mm 1 91 48 5 mm Foam tank case unit Foam soap dispenser Foam soap dispenser Note Deck mount foam soap dispenser shown mounted with faucet for refer...

Page 3: ...not install in areas with high humidity or where the unit may be exposed to direct sunlight Install the unit on a sturdy horizontal surface that is in ambient temperature 0 35 C 32 95 F Make sure foam...

Page 4: ...foam soap dispenser Use the mounting bracket as a guide mark where holes need to be drilled Important Make sure bracket and foam tank case unit is mounted level When installing onto a concrete wall d...

Page 5: ...ing the connector case Remove liner and affix one side of the adhesive pad to the back of the connector case Remove the adhesive liner on the pad affixed on the connector case and attach to the unders...

Page 6: ...dry cloth If the unit is seriously polluted on portions other than the hand sensor use wet cloths properly diluted neutral detergent Then remove the detergent with a soft damp cloth and then rub with...

Page 7: ...d sensor periodically about once a month according to the following procedure Press the operation switch to OFF the operation light goes off Gently wipe the hand sensor area with a cloth moistened wit...

Page 8: ...iner See the Safety Data Sheets Eye Contact Flush eyes with water for a minimum of 15 minutes and consult a physician immediately Ingestion Drink water to induce vomiting and consult a physician immed...

Reviews: