CLEANING THE DISPENSER
If the tip of the soap nozzle is clogged, the
dispensing capability may fail or function
partially. Clean the nozzle according to the
following procedure:
• Press the operation switch to OFF (the
operation light goes off).
• Remove the nozzle using a 2.5 mm Hex
key. Next, remove the internal mesh. Wash
it with lukewarm water.
• Insert the mesh and then the nozzle back
into the spout and tighten with the hex key.
• Turn ON the operation switch (the operation
light goes on). Check the foam soap
spraying state.
• Repeat as needed
SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131
Phone: 1.800.982.5839 or 1.847.671.4300 • Fax: 1.800.447.8329 or 1.847.671.4380 • sloan.com
Copyright © 2022 SLOAN VALVE COMPANY
TOP FILL SOAP DISPENSER INSTALLATION GUIDE - CONTINUED
Insert the small tube over the pump outlet.
Insert the Fill Tube over the Pump
Assembly connector.
Connect the Yellow Data Connector.
Connect the Power Connector to battery
box or AC adaptor.
The Spout indicator light will alternate between
RED and YELLOW for 15 seconds.
10
See next page for filling