CLEANING THE DISPENSER

If the tip of the soap nozzle is clogged, the 
dispensing capability may fail or function 
partially. Clean the nozzle according to the 
following procedure:
• Press the operation switch to OFF (the   
   operation light goes off).
• Remove the nozzle using a 2.5 mm Hex     
   key. Next, remove the internal mesh. Wash    
   it with lukewarm water.
• Insert the mesh and then the nozzle back 
   into the spout and tighten with the hex key.
• Turn ON the operation switch (the operation 
   light goes on). Check the foam soap 
   spraying state.
• Repeat as needed

SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131

Phone: 1.800.982.5839 or 1.847.671.4300 • Fax: 1.800.447.8329 or 1.847.671.4380 • sloan.com

Copyright © 2022 SLOAN VALVE COMPANY

TOP FILL SOAP DISPENSER INSTALLATION GUIDE - CONTINUED

Insert the small tube over the pump outlet.

Insert the Fill Tube over the Pump

Assembly connector.

Connect the Yellow Data Connector.

Connect the Power Connector to battery

box or AC adaptor.

The Spout indicator light will alternate between 

RED and YELLOW for 15 seconds. 

10

See next page for filling 

instructions