background image

BLOWER MOTOR 

4 PIN CABLE 

GROUND  

PROGRAMMING 
CABLE 

3

2 - CONNECT HOSE

BASYS DRYER 
SPOUT 

LOCKING NUT
WASHER

HOSE 

SPOUT 
SHANK 

BLOWER MOTOR 

A

B

C

D

A

B

C

D

Align slots in flared connector end of hose with shank guides. 
Slide over the spout shank until it stops. Rotate the flared con-
nector clockwise until it locks into place (will feel it snap into 
place).
 

A

B

C

D

A

B

C

D

3- CONNECT WIRES

BLOWER MOTOR 

GROUND  

4 PIN CABLE 

PROGRAMMING 
CABLE 

A

B

C

D

A

B

C

D

Plug the four (4) pin cable from the spout into 
the Four (4) pin socket on the Hand Dryer 
Motor. Plug the ground cable into the ground 
tab on the Blower Motor.
 

A

B

C

D

A

B

C

D

Leave the Programming Cable unattached. Do not
remove or cut-off cable. Cord can be bundled.

Align slots of round squared connector end of hose 
to opening guides on hand dryer motor into the 
opening until it stops, rotate the connector 
counterclockwise until it locks into place.

CARE AND CLEANING

Important:
DISCONNECT ELECTRICAL SUPPLY TO DRYER PRIOR TO SERVICING.

Gently wash spout using a soft cloth or sponge and a mild soap or detergent with lukewarm water to loosen dirt and grime.

CLEANING SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL

With normal use, dryer will require cleaning once a year. Heavier usage requires more frequent cleaning. Use a small, soft 
brush to gently clean all parts.