BLOWER MOTOR
4 PIN CABLE
GROUND
PROGRAMMING
CABLE
3
2 - CONNECT HOSE
BASYS DRYER
SPOUT
LOCKING NUT
WASHER
HOSE
SPOUT
SHANK
BLOWER MOTOR
A
B
C
D
A
B
C
D
Align slots in flared connector end of hose with shank guides.
Slide over the spout shank until it stops. Rotate the flared con-
nector clockwise until it locks into place (will feel it snap into
place).
A
B
C
D
A
B
C
D
3- CONNECT WIRES
BLOWER MOTOR
GROUND
4 PIN CABLE
PROGRAMMING
CABLE
A
B
C
D
A
B
C
D
Plug the four (4) pin cable from the spout into
the Four (4) pin socket on the Hand Dryer
Motor. Plug the ground cable into the ground
tab on the Blower Motor.
A
B
C
D
A
B
C
D
Leave the Programming Cable unattached. Do not
remove or cut-off cable. Cord can be bundled.
Align slots of round squared connector end of hose
to opening guides on hand dryer motor into the
opening until it stops, rotate the connector
counterclockwise until it locks into place.
CARE AND CLEANING
Important:
DISCONNECT ELECTRICAL SUPPLY TO DRYER PRIOR TO SERVICING.
Gently wash spout using a soft cloth or sponge and a mild soap or detergent with lukewarm water to loosen dirt and grime.
CLEANING SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL
With normal use, dryer will require cleaning once a year. Heavier usage requires more frequent cleaning. Use a small, soft
brush to gently clean all parts.