background image

Repair Parts and Maintenance Guide

132

The information contained in this document is subject to change without notice.

BASYS

®

 

Infrared Sensor Activated

As the user’s hands enter the 

beam’s effective range, the beam 

is refl ected back into the sensor 

receiver and activates the solenoid 

valve allowing water to fl ow from 

the faucet. Water will fl ow until 

the hands are removed or until the 

faucet reaches its automatic time 

out limit setting.

OPERATION

SET AND FIX TEMPERATURE AND ADJUST HOT LIMIT STOP

Adjust lever to set temperature.

Optional — To fi x temperature, 

set lever to the desired position, 

then remove lever and plug hole 

with Cap.

2 mm

Faucet may be adjusted in 10º 

increments.

This feature will operate the faucet 

every 12 or 24 hours since last 

use, if not used to prevent stagnant 

water conditions.
Default purge duration is 

two minutes.
Consult factory regarding 

other timing options.
IR activation (see above). Cover IR 

clic approximately 24 sec. (ignore 

LED indications during this period). 

Release when requested program 

is reached. (See diagram to right). 

Programming mode will time out 

after 2 minutes if no changes 

are made.

12/24 LINE PURGE FEATURE

1x 24 sec 

...1x

...2x

...3x

+

 ...

Activate 12HR

Deactivate

Activate 24HR

1x 24 sec 

...1x

...2x

...3x

+

 ...

Activate 12HR

Deactivate

Activate 24HR

Optional Hot Limit Stop 

Adjustment — To adjust the hot/

cold mix (factory set at 50/50) 

remove the lever.
Check to make sure dot is 

in center position before 

beginning adjustment.

2 mm

  

Steps to  

Default  IR

 Function 

Activate  Function 

Setting 

Clic

 

IR Activation

  Cover IR clic approximately for 2 sec.  

–– 

––

  

until LED will fl ash GREEN 1x - then remove 

  

fi nger from IR clic (Active for 5 sec.) 

 

Cleaning

 

IR activation; Cover IR clic 2x - confi rmation  

2 min. 

––

 

Mode

 

of the function is active by a couple fl ashes 

  

by the LED; to return to normal operation cover 

  

IR clic 1x or the faucet will automatically return 

  

to normal function after 2 min.

 

12/24

 

Line

 

See below. 

Off 

Off

 

Purge

  

  12HR

 

Feature

  

  24HR

 

Sensor

 

See page 123. 

1-8

 

Range

 

Adjustment

 

Reset

 

IR activation; Cover IR clic 2x; LED will fl ash 5x 

Manually  ––

 

Electronics

 

Cover IR clic 1x for 5 sec. until LED 

  

fl ashes 4x, then remove fi nger from IR clic

  

Wait for 20 sec.

  

(After 10 sec. water will fl ow for 6 sec. 

  

and automatically adjust to environment)

Security Off

 

After 90 seconds (max) of hand and/or object  

On 

––

  

within sensor appears permanent, waterfl ow 

  

will stop and will remeasure environment

Please contact factory for more extensive programming options.

Faucets and  Soap Dispensers

Repair Parts and Maintenance Guide

133

The information contained in this document is subject to change without notice.

BASYS

®

 

Infrared Sensor Activated

Factory setting is appropriate for the majority of applications and 

should not require resetting unless under extreme situations.

Wait, until LED fl ashes GREEN.

IR Activation (see previous page).To enter programming mode place fi nger 

on IR clic for 2 times then remove. Light on side of crown should blink to 

indicate programming mode. 

SENSOR RANGE ADJUSTMENT

BATTERY REPLACEMENT

2x + 

1x 5 sec

1x

2x

3x

4x

6x - Factory Setting

7x

8x

5x

NOTE: Replace Battery when LED1 indicator fl ashes red each time 

faucet is in use or when faucet stops functioning. LED1 is identifi ed 

by the battery symbol.
NOTE: Turning off water is not necessary.

Remove crown by loosening hex screw 

located on underside of spout and slide 

crown down and lift off.

NOTE: Screw is captive within 

faucet body and will not fall out.

Remove battery pack assembly by 

lifting out of spout.

Open battery pack assembly by pushing 

in tabs on side of assembly.

Remove all four (4) AA-cell batteries 

from battery pack.
Insert four (4) NEW AA-cell batteries 

into battery pack assembly cartridge.

NOTE: Insure batteries are installed 

with proper polarity. The cover 

of the case indicates polarity of 

batteries. Improper polarity will 

not harm the faucet. Improper 

polarity will cause the faucet not to 

operate.

Replace cover of the battery pack 

assembly and reinsert assembly into 

faucet.

Slide on crown and secure.

UNLOCK

LOCK

SPARE

FILTER

2x + 

1x 5 sec

1x

2x

3x

4x

6x - Factory Setting

7x

8x

5x

2x + 

1x 5 sec

1x

2x

3x

4x

6x - Factory Setting

7x

8x

5x

2x + 

1x 5 sec

1x

2x

3x

4x

6x - Factory Setting

7x

8x

5x

UNLOCK

LOCK

Cover IR clic until LED fl ashes 4x - hold on until LED fl ashes 1x to 8x, from 

minimum to maximum. See diagram below. Release when requested range 