Repair Parts and Maintenance Guide
132
The information contained in this document is subject to change without notice.
BASYS
®
Infrared Sensor Activated
As the user’s hands enter the
beam’s effective range, the beam
is refl ected back into the sensor
receiver and activates the solenoid
valve allowing water to fl ow from
the faucet. Water will fl ow until
the hands are removed or until the
faucet reaches its automatic time
out limit setting.
OPERATION
SET AND FIX TEMPERATURE AND ADJUST HOT LIMIT STOP
Adjust lever to set temperature.
Optional — To fi x temperature,
set lever to the desired position,
then remove lever and plug hole
with Cap.
2 mm
Faucet may be adjusted in 10º
increments.
This feature will operate the faucet
every 12 or 24 hours since last
use, if not used to prevent stagnant
water conditions.
Default purge duration is
two minutes.
Consult factory regarding
other timing options.
IR activation (see above). Cover IR
clic approximately 24 sec. (ignore
LED indications during this period).
Release when requested program
is reached. (See diagram to right).
Programming mode will time out
after 2 minutes if no changes
are made.
12/24 LINE PURGE FEATURE
1x 24 sec
...1x
...2x
...3x
+
...
Activate 12HR
Deactivate
Activate 24HR
1x 24 sec
...1x
...2x
...3x
+
...
Activate 12HR
Deactivate
Activate 24HR
Optional Hot Limit Stop
Adjustment — To adjust the hot/
cold mix (factory set at 50/50)
remove the lever.
Check to make sure dot is
in center position before
beginning adjustment.
2 mm
Steps to
Default IR
Function
Activate Function
Setting
Clic
IR Activation
Cover IR clic approximately for 2 sec.
––
––
until LED will fl ash GREEN 1x - then remove
fi nger from IR clic (Active for 5 sec.)
Cleaning
IR activation; Cover IR clic 2x - confi rmation
2 min.
––
Mode
of the function is active by a couple fl ashes
by the LED; to return to normal operation cover
IR clic 1x or the faucet will automatically return
to normal function after 2 min.
12/24
Line
See below.
Off
Off
Purge
12HR
Feature
24HR
Sensor
See page 123.
6
1-8
Range
Adjustment
Reset
IR activation; Cover IR clic 2x; LED will fl ash 5x
Manually ––
Electronics
Cover IR clic 1x for 5 sec. until LED
fl ashes 4x, then remove fi nger from IR clic
Wait for 20 sec.
(After 10 sec. water will fl ow for 6 sec.
and automatically adjust to environment)
Security Off
After 90 seconds (max) of hand and/or object
On
––
within sensor appears permanent, waterfl ow
will stop and will remeasure environment
Please contact factory for more extensive programming options.
Faucets and Soap Dispensers
Repair Parts and Maintenance Guide
133
The information contained in this document is subject to change without notice.
BASYS
®
Infrared Sensor Activated
Factory setting is appropriate for the majority of applications and
should not require resetting unless under extreme situations.
Wait, until LED fl ashes GREEN.
IR Activation (see previous page).To enter programming mode place fi nger
on IR clic for 2 times then remove. Light on side of crown should blink to
indicate programming mode.
SENSOR RANGE ADJUSTMENT
BATTERY REPLACEMENT
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
NOTE: Replace Battery when LED1 indicator fl ashes red each time
faucet is in use or when faucet stops functioning. LED1 is identifi ed
by the battery symbol.
NOTE: Turning off water is not necessary.
Remove crown by loosening hex screw
located on underside of spout and slide
crown down and lift off.
NOTE: Screw is captive within
faucet body and will not fall out.
Remove battery pack assembly by
lifting out of spout.
Open battery pack assembly by pushing
in tabs on side of assembly.
Remove all four (4) AA-cell batteries
from battery pack.
Insert four (4) NEW AA-cell batteries
into battery pack assembly cartridge.
NOTE: Insure batteries are installed
with proper polarity. The cover
of the case indicates polarity of
batteries. Improper polarity will
not harm the faucet. Improper
polarity will cause the faucet not to
operate.
Replace cover of the battery pack
assembly and reinsert assembly into
faucet.
Slide on crown and secure.
UNLOCK
LOCK
SPARE
FILTER
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
UNLOCK
LOCK
Cover IR clic until LED fl ashes 4x - hold on until LED fl ashes 1x to 8x, from
minimum to maximum. See diagram below. Release when requested range
is reached.
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 130
9/18/17 7:53 AM