5.2 Door panel and camera image view

Standby mode

Monitor will display 

the image from the 

first door panel

(monitoring time – 60 seconds)

Monitor will display 

the image from the 

second door panel

(monitoring time – 60 seconds)

Press «Monitor» 
button on the
monitor

20 seconds

Standby mode

Press «Monitor» 
button on the
monitor again

Press «Monitor» 
button on the
monitor again

Press «Monitor» 
button on the
monitor again

Press «Monitor» 
button on the
monitor again

Monitor will display 

the image from the 

first CCTV camera

(monitoring time is unlimited)

Monitor will display 

the image from the 

second CCTV camera

(monitoring time is unlimited)

Press «Hang up» button to
stop monitoring or
conversation

Press «Answer» button to start
conversation with the visitor

Press «Unlock» button to open
lock connected to the current
door panel, relay built into the 
panel will open the lock

5.3 Incoming call redirection

Two monitors connected into one system are used.

Notes:

1) If only one door panel connected to the monitor then you can escape monitoring mode by pressing 
«Monitor»       

    

button one more time. (all other sources of video signal should be disabled in the monitor 

settings).
2) If several monitors connected into one system, the user can view the image from door panels and 
cameras on any monitor inside this system. The image will be transferred from the «Master» monitor door 
panels and cameras to the «Slave» monitors.
3) If someone press call button on the door panel while monitoring is active then the image from this door 
panel appears on the monitor screen and call melody starts. Press «Answer»

 

        button to start 

conversation.

Note:

If  incoming call was successfully redirected to the other monitor and other user answered the call then 
current monitor will enter standby mode.

Melody starts ringing on
the other monitor inside

the system and visitor image 

appears on the monitor screen

Conversation with the 

visitor on the other 

monitor begins

Incoming call from the 

door panel and the 

user starts conversation

Press  «Answer» 
button to start
call redirection

20 seconds

Press «Answer» button on the 
other monitor to start
conversation with the visitor

Standby mode

Press «Unlock» button to open
lock connected to the current
door panel, relay built into the 
panel will open the lock

Press «Hang up» button to
stop conversation or
incoming call

Summary of Contents for SM-04M

Page 1: ... Design Uniqueness Innovation DESIGN DIRECT SERIES SM 04M 4 video door phone Thank you for the choice of our equipment User manual ...

Page 2: ...ct influence of the natural phenomena such as direct sunlight rain or snow Don t use aggressive or abradant detergent for the device surface cleaning Use soft wet cloth or tissue to remove strong dirt Don t overpower outlets It can cause fire or electric shock Nature protection Don t throw away the device with other industrial or nutritive trash if you see that symbol Some regions have separation ...

Page 3: ...move joystick up or down to move through the settings menu next previous parameter push the joystick on any parameter to change its value Change the value of current parameter by moving joystick up or down and then push the joystick again to save the parameter Microphone 169 mm 118 mm 20 mm Screen Resolution Video system Audio type Call time Internal memory Memory extension slot Standby mode power...

Page 4: ... Shielded or non shielded twisted pair not recommended distance up to 25 meters non shielded twisted pair can be used distance 25 to 50 meters shielded twisted pair should be used Power Audio Ground Video Power Audio Ground Video Power Audio Ground Video Power Audio Ground Video Power Audio Ground Video Power Audio Ground Video 0 50 m Shield Shield 50 80 m 80 100 m RG 59 or RG 6 0 25 m 25 50 m Pow...

Page 5: ...anel appears on the monitor screen Visitor presses call button on the first door panel Visitor presses call button on the second door panel Press Answer button to start conversation with the visitor Melody stops ringing and conversation starts talking time is 120 seconds Press Hang up button to stop conversation or incoming call Press Unlock button to open lock connected to the current door panel ...

Page 6: ...mode by pressing Monitor button one more time all other sources of video signal should be disabled in the monitor settings 2 If several monitors connected into one system the user can view the image from door panels and cameras on any monitor inside this system The image will be transferred from the Master monitor door panels and cameras to the Slave monitors 3 If someone press call button on the ...

Page 7: ... exit from the display settings Also you can press button to exit Note If someone press call button on the door panel while intercom is active then the image from this door panel appears on the monitor screen and call melody starts Press Answer button to start conversation with the visitor 6 Monitor settings Settings joystick situated on the right side of the monitor case It has several functions ...

Page 8: ...the user haven t offend transporting installation and working conditions This limited warranty does not cover any damage to the product that results from improper installation accident abuse misuse natural disaster insufficient or excessive electrical supply abnormal mechanical or environmental conditions or any unauthorized disassembly repair or modification Warranty void in such cases the produc...

Reviews: