Sleipner SX35POD Installation Manual Download Page 13

 13

6398

12

2022

-

HydroPOD 35 & 50

MG_0145

*Cowl

*Grid

Grids and cowls can not be installed in 

combination. Only one option is possible 

at a time.

Tighten 2Nm

Correct rotation of the grid/ cowl requires the longer 

spaced bolts at the top and the shorter spaced bolts at 

the bottom

MC_0479

Electrical Installation

WARNING 

Check the following with the main switch is set to off. After all electrical connections have been completed check with an ohm meter that 

there is no electrical connection between 

1. electro-motor flange and the positive terminal on the motor 

2. electro-motor flange and the battery negative terminal on the motor 

(If unsure contact skilled personnel.)

1.   Plan the location of all electrical components before starting with the electrical installation. Main electrical components will typically consist of 

battery, fuse, main switch, Proportional Power Controller (PPC) and Control Box, see Wiring Diagram chapter for an overview. 

For safety reasons it is always recommended to install a fuse and a main switch on the power cable and as close as possible to the positive battery 

pole. Distance between battery and fuse should be less than 1 meter. The main switch must be installed such that is easily accessible to disconnect 

the thruster when not on-board or in the case of an emergency. Sleipner offers both manual main switches and Automatic Main Switches (AMS). 

Sleipner AMS is controlled by the control panel in addition to the option of manual operation. Turning on the control panel does also turn on the 

automatic main switch. When the control panel is turned off the automatic main switch is also turned off. This ensures that the control electronics 

and motor is only energized when the control panel is turned on. Sleipner offers AMS supporting either S-Link or ON/OFF control panels. Ensure to 

select a main switch with voltage and current ratings according to the specifi cations of the chosen thruster motor. Note that the AMS requires separate 

power supply which should be protected by a dedicated fuse.

For installations which requires ignition protected equipment ensure to use ignition protected fuse and main switch. Ensure to follow your national 

regulations.

2.   Estimate the total length of the power cables to determine the recommended cross section. The total power cable length is defi ned as the 

distances from the positive battery pole, via fuse, main switch and PPC to the Control Box and all the way back to the negative battery pole. 

Compromising the cable sections named B+, M- and B- on the drawing in the Wiring Diagram chapter. 

3.   Find the recommended power cable cross section for you installation by using the estimated total power cable length and the table shown in 

Electrical Reference Guide chapter. Note that maximum cross section that fi ts through the grommet of the Control Box is 70mm2. Maximum 

cross section that fi ts with the power cable terminal inside the Control Box is 50mm2. If a 70mm2 cable is used some of the wire strands must be 

cut off to fi t the cable inside the terminal. If recommended cross section exceeds 70mm2 it is recommended to use as short as possible cables 

between PPC and Control Box with maximum 70mm2 cross section. The recommended cross section or larger should then be used for the rest of 

the power cables. 

4.   Find the recommended fuse rating by using the table shown in Electrical Reference Guide chapter. Use slow blow rated fuses to hold stated 

nominal current for minimum 5 minutes. 

5.   Select appropriate dimensioned battery with Cold Cranking Amps (CCA) according to according to recommendations in Electrical Reference 

Guide chapter. Battery voltage must be compliant with the voltage rating of the thruster motor and control circuitry. Capacity and rated discharge 

current of battery should be according to rated nominal current drawn and typical duty cycle for thruster operation. Nominal current drawn is 

listed in Electrical Reference Guide chapter. The actual voltage at the motor while running the thruster determines the motor RPM and thrust. 

Cable losses can reduce the voltage level and result in reduced thrust. Use larger cable cross section and high-capacity battery for improved 

performance. 

6.   Install the Control Box according to instructions in Control Box Installation chapter. 

7.   Install the control panel according to instructions in the installation manual of the selected Control Panel.

8.   Install the battery, fuse, main switch and wiring according to instructions in Wiring Diagram chapter and installation manual of selected fuse and 

main switch. 

Electrical Reference 

Guide

MC_0077

Model Size

System 

Voltage

Nominal 

current 

draw

Min. battery 

CCA

Rec. 

fuse

Cross Section Guide for Power Cables

Unit

<7m 

total + & -

7-14m 

total + & -

15-21m 

total + & -

22-28m 

total + & -

28-35m 

total + & -

36-45m 

total + & -

Min.

Rec.

Min.

Rec.

Min.

Rec.

Min.

Rec.

Min.

Rec.

Min.

Rec.

35/140

12V

245 A

DIN: 200 

SAE: 380 

EN: 330

ANL 150

mm²

35

50

50

70

70

95

95

120

120

2 x 70

2 x 70

2 x 95

AWG

2

1/0

1/0

2/0

2/0

3/0

3/0

4/0

4/0

2 x 2/0

2 x 2/0

2 x 3/0

50/140S

12V

370 A

DIN: 350 

SAE: 665 

EN: 600

ANL 325

mm²

50

50

70

95

120

2 x 70

2 x 70

2 x 95

2 x 95

2 x 120

2 x 120

2 x 120

AWG

1/0

1/0

2/0

3/0

4/0

2 x 2/0

2 x 2/0

2 x 3/0

2 x 3/0

2 x 4/0

2 x 4/0

2 x 4/0

Summary of Contents for SX35POD

Page 1: ...ER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway www sleipnergroup com DOCUMENT ID REVISION DATE LANGUAGE Installation Guide For DC External POD Electric Thruster Models SX35POD SX50POD EN I M 6398 1...

Page 2: ...ecautions Guidelines 3 Product Measurements 4 5 Product Specifications 6 Positioning of the SX with Hydrodynamical Cover 7 Tunnel Installation 8 Hydropod Modification 9 Hydropod Installation 10 Propel...

Page 3: ...es NEVER Disassemble any part of the Ignition Protected assembly Tampering with the Ignition Protected assembly will cause it to lose this safety feature If there is a problem with your Ignition Prote...

Page 4: ...7 08 H Tube Height 183 7 20 183 7 20 W Width 183 7 2 183 7 2 L Length 630 24 8 630 24 8 a Measurement 129 5 08 129 5 08 b Measurement 213 8 4 213 8 4 c Measurement 218 8 6 218 8 6 d Measurement 68 2 7...

Page 5: ...5 6398 12 2022 HydroPOD 35 50 MG_0132 121 mm 4 76 187 mm 7 36 170 mm 6 69 136 mm 5 35 110 mm 4 33 Product Measurements...

Page 6: ...in duty cycle at 20 c ambient temperature S2 motor at 2 3 min duty cycle at 20 c ambient temperature Power 1 8kw 2hp 2 8kw 3 75hp Weight 15 3 kg 33 73 lbs 15 3 kg 33 73 lbs Product SX35 SXP35 SX50 SXP...

Page 7: ...Cover Aim to install the thruster as far forward Aft as possible Due to the leverage effect around the boats pivot point The relative distance difference from the boat pivots point to the thruster wi...

Page 8: ...tabs into the motor inserts 1 Tunnel Installation 1 Connect both ends of the tunnel to the thruster motor All hooks must be completely interlocked making the inside of the tunnel smooth NB Ensure tun...

Page 9: ...ess is 50mm 2 Drill main hole for the cable tube then two support bolt holes 3 Place the SX thruster into the Hydro pod mould 4 Place the hydro pod with the SX thruster on the hull Use the pre drilled...

Page 10: ...s to length top achieve 15 compression 4 Apply a sealant MS Polymer to IF required to fill gaps between the Hydro pod and the hull use an the inside surface of the cut out holes on the hull appropriat...

Page 11: ...th the internal slot in the propeller 2 Insert the washer to the end of the shaft spline Tighten with the propeller lock nut 3 Apply anti fouling to the gear leg and propeller Do not apply anti foulin...

Page 12: ...of the cowls ensure the appropriate twist of the cowl to direct water away from obstacles MG_0145 Cowl Grid Grids and cowls can not be installed in combination Only one option is possible at a time Ti...

Page 13: ...you installation by using the estimated total power cable length and the table shown in Electrical Reference Guide chapter Note that maximum cross section that fits through the grommet of the Control...

Page 14: ...be mounted in any orientation preferably with cables facing down The control box must be positioned within 0 75 meters from the thruster attachment bolts Ensure that the SX Thruster Hose will not obs...

Page 15: ...marked A1 and A2 and should be fastened to the terminal with corresponding marking Place the ring cable lug connected to the white wire between the lug of the motor power cable and the nut Fasten the...

Page 16: ...l Box 4 lead cable SX thruster hose SX POD thruster B B THRUSTER BATTERY 12V Control panel Refer to your control panel manual for detailed information on connecting the SX system to your control devic...

Page 17: ...ntrol Panel installation please refer to the Installation Guide accompanying the control panel to be installed MC_0398 Control Panel SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway www sleipne...

Page 18: ...orrect cable fuse and main switch size No water leakage around hull penetrated studs Check that there is no electrical connection between the electro motor body and positive terminal on the motor and...

Page 19: ...nces of the defect to the best of the Claimant s knowledge including product identification and serial nbr the date and place of purchase and the name and address of the installer Proof of purchase da...

Page 20: ...curacies or omissions it may contain Continuous product improvement may change the product specifications without notice Therefore Sleipner Group cannot accept liability for any possible differences b...

Reviews: