14
6399
11
2021
-
HydroPOD 35 & 50
Control Box Installation
The control box is the central component that can be connected to several other control panels. The control box can be mounted in any orientation,
preferably with cables facing down.
(NB: The control box must be positioned within 0,75 meters from the thruster assembly with the provided
cables and not near any object that radiate high temperatures.)
1. Defi ne the location to install the control box.
(NB: Ensure cables will not obstruct any objects.)
2. Mark the locations of the four drill holes and drill the holes.
3. Attach cables to the control box
(NB: the control box internal components can be removed via its attachment screws for easier installation
using thick battery cables.)
4. Tighten hose clamps in order to ensure Ignition Protection as illustrated.
5. Fasten the control box to the hull.
MC_0075
!
Please refer to the graphic for special considerations relating to your model
!
IMPORTANT
It is the installers full responsibility to follow instructions and ensure total Ignition Protection.
MG_0211
BAT. -
5, 6 Nm
Control Box
hose clamp
Hose claps
BAT. +
5, 6 Nm
MOTOR CABLE -
5Nm
# SX
*P
35 CONTROL BOX
TORQUE 8Nm
MOTOR CABLE +
5Nm
BAT. -
5, 6 Nm
BAT. +
5, 6 Nm
MOTOR CABLE -
5Nm
# SX
*P
50 CONTROL BOX
TORQUE 8Nm
MOTOR CABLE +
5Nm
*P- Propositional
*P- Propositional
MG_0126
8-lead cable
A1
A2
Temp switch
NC
NTC
PPC
Proportional Power
Controller PPC
Min
200mm
Min
100mm
Min
100mm
B+
B-
CONTROLLER
8-lead cable
++
*C
BLUE PROTECTION
SLEVE
(900mm/ 35”)
IP
configuration
Non-IP
configuration
THRUSTER
(MUST BE IGNITION PROTECTED IF
LOCATED IN IP REQUESTED AREA)
Automatic MAIN
SWITCH
THRUSTER
BATTERY
12V
Minimum and recommended cable dimensions can be identical due to safety margins and cable heat considerations for short cable lengths.
* Minimum or recommended cable cross section in mm2
B-
B+
+
-
*D
MAIN FUSE
S-link
spur
cables
S-link
backbone
CONTROLLER CONNECTIONS:
<<B+>>: Power supply pos from thruster battery/ Main switch/ Main fuse
<<B->>: Power supply neg from thruster battery
2 Motor cables from thruster
4 wires from thruster overtemp switch
2 Control cables from control panel(s)/ remote
**Automatic or
Manual main switch
(See Main Switch