SLC PIX BAR PRO Quad 12 User Manual Download Page 4

PRO PAR Quad 12 

User Manual 

 

PRO PAR Quad 12 

P a g e

 | 

Stage Light Company, LLC 

 

 

© 

2014 

DMX Values 

10 Channels Mode 

Channel  Value 

Function 

 

000-255  Red 0% ~ 100% 

 

000-255  Green 0% ~ 100% 

 

000-255  Blue 0% ~ 100% 

 

000-255  White 0% ~ 100% 

 

000-255  Master Dimmer 0% ~ 100% 

 

000-009  Strobe OFF 

 

010-255  Strobe (Slow ~ Fast 1-30Hz) 

000-019  No Function 

 

020-039  Red 100% / Green 0%~100% / Blue 0% 
040-059  Red 100%~0% / Green 100% / Blue 0% 
060-079  Red 0% / Green 100% / Blue 0%~100% 
080-099  Red 0% / Green 100%~0% / Blue 100% 
100-119  Red 0%~100% / Green 0% / Blue 100% 
120-139  Red 100% / Green 0% / Blue 100%~0% 
140-159  Red 100% / Green 0%~100% / Blue 0%~100% 
160-179  Red 100%~0% / Green 100%~0% / Blue 100% 
180-200  Red 100% / Green 100% / Blue 100% / White 100% 
201-204  Color Temperature 1 

WARM 

 

 

 
 

 

 
 

 

 

COOL 

205-209  Color Temperature 2 
210-214  Color Temperature 3 
215-219  Color Temperature 4 
220-224  Color Temperature 5 
225-229  Color Temperature 6 
230-234  Color Temperature 7 
235-239  Color Temperature 8 
240-244  Color Temperature 9 
245-249  Color Temperature 10 
250-255  Color Temperature 11 

000-009  No Function 

 

010-057  Auto Program 1 

R G B W colors switching 

058-106  Auto Program 2 

15 colors switching 

107-155  Auto Program 3 

R G B W colors fading 

156-204  Auto Program 4 

15 colors fading 

205-255  Auto Program 5 

Color macros fading 

000-255  Speed of Auto Programs (Slow ~ Fast) 

 

10 

000-009  Use the dimmer of control board setting 

 

010-069  Linear Dimmer 
070-130  Non-Linear Dimmer 1 
131-191  Non-Linear Dimmer 2 
192-255  Non-Linear Dimmer 3 

 

 

 

Reviews: