3. Control Signal Jumper Settings
Header JP6 is an 8x3, 100 mil header stake that provides access to the eight OE pins allowing easy enable or disable of individual
outputs. Table below defines how to configure each input.
Table 3.1. Control Input Jumper Configuration Settings
Control Input Pin
LO
NONE
HI
OE_0b
Enable
Enable
Disable
OE_1b
Enable
Enable
Disable
OE_2b
Enable
Enable
Disable
OE_3b
Enable
Enable
Disable
OE_4b
Enable
Enable
Disable
OE_5b
Enable
Enable
Disable
OE_6b
Enable
Enable
Disable
OE_7b
Enable
Enable
Disable
Enable/disable times can be measured by connecting an external pulse generator to the middle pin of the header and GND to the “LO”
pin and sending this signal to trigger a scope. By measuring the time differential between the rising (falling) edge of the trigger and last
(first) output clock edge of the corresponding output, the user can determine the disable (enable) time for that output.
UG337: Si53208-EVB User’s Guide • Control Signal Jumper Settings
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
Rev. 0.1 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021