Si53119-EVB
6
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
Rev. 0.1 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 17, 2021
5. Usage of the EVB
Once the EVB has been set up, the following can be evaluated:
1. Signal integrity of the device when driving 10-inch, 100-ohm differential traces.
2. Effect of capacitance load on output signal integrity.
3. Output-to-output skew over 10-inch traces.
4. Input-to-output prorogation delay in BYPASS, HBW, and LBW modes using the input clock return path.
5. Measuring the power consumption of the device.
6. Modification of the device settings via the I
2