background image

MODEL Nos:                             TLINV1500 TLINV1500/24

Output power continuous

1500W

1500W

Output power surge

3000W

3000W

AC 0utput voltage

230V

230V

Regulation

±5%

±5%

Output wave form

Modified Sine Wave

Modified Sine Wave

DC input voltage

10-15V

20-30V

Low battery alarm

10.7V

21.5V

Low battery shut-down

10V

20V

Frequency ±1%

50Hz

50Hz

Efficiency

80-90%

80-90%

No load current draw

<0.6A

<0.3A

Over temperature protection

55°C ±5°C

55°C ±5°C

Cooling fan

YES

YES

Overload protection

YES

YES

lnput short circuit protection

YES

YES

Dimensions (LxWxH)

430 x 240 x 77mm

430 x 240 x 77mm

Net weight

3.8kgs (approx.)

3.8kgs (approx.)

www.tlc-direct.co.uk

Summary of Contents for 651.583

Page 1: ...Operation Manual Model Model TL INV 1500 TL INV 1500 24 12V 1500W 24V 1500W 230 VOLT INVERTERS...

Page 2: ...ut voltage 10 15V 20 30V Low battery alarm 10 7V 21 5V Low battery shut down 10V 20V Frequency 1 50Hz 50Hz Efficiency 80 90 80 90 No load current draw 0 6A 0 3A Over temperature protection 55 C 5 C 55...

Page 3: ...wer which can run all kinds of household products such as kitchen appliances microwaves power tools TVs radios computers and more You just connect the inverter to a battery and plug your AC devices in...

Page 4: ...ected battery must be in good condition and fully charged After some time it may be necessary to start the car or boat in order to recharge the battery At that moment the inverter must be switched OFF...

Page 5: ...polarity will damage the inverter and is not covered under warranty 3 Ensure the DC input connections are secure because a loose contact can result in excessive voltage drop and can cause overheated...

Page 6: ...ry Red is positive and black is negative 3 Earth ground terminal Replacement of the connection cables If it is necessary to replace the battery cables you can use soldering cables Always use cables wi...

Page 7: ...pacity as you will have more reserve and the battery will not be discharged as deeply To obtain sufficient battery capacity you may need to use more than one battery Two identical batteries can be con...

Page 8: ...AC inverters have been around for a long time Energy loss in this conversion process at first was very high the average efficiency of early inverters hovered around 60 In other words you would have t...

Page 9: ...stage of three stage battery charging Current is sent to batteries at the maximum rate they will accept while voltage rises to full charge level Current The rate of flow of electrical charge The flow...

Page 10: ...and lights are examples of electrical loads Low Battery Protection A control circuit that stops the flow of electricity from batteries to loads when battery voltage drops to dangerously low levels Mod...

Page 11: ...their continuous ratings Volts A unit of measure of the pressure in an electrical circuit Volts are a measure of electric potential Voltage is often explained using a liquid analogy comparing water pr...