background image

REV. 1-6-12  Page 4

WARNING: 

Proper clearances from combustible, construction and materials must be maintained from all sides, top and 

bottom of this appliance.  This appliance should never be placed on any combustible surface.  This appliance should 

never be placed under any combustibles closer then 96-inches. This appliance should never be placed closer than 
36-inches from any side to any combustible construction or materials (See fig. 2, page 3).

PREPARING A NON-COMBUSTIBLE STRUCTURE

The Fire Pit is to be installed on a flat, stable surface, away from any combustible materials. Install Fire Pit on any level, 

outdoor non-combustible surface. 

NOTE

: Do not place fire pit directly on grass, dirt, or rocks this may prevent proper 

ventilation (Fig. 1, pg. 3).  

HARD PIPING TO FIRE PIT WITHOUT GAS PROXIMITY

1. Turn 

OFF

 gas supply system. 

NOTE

: All gas connections (except for brass to brass) require the following. Clean pipe 

threads using either a wire brush or steel wool. Apply Teflon tape or pipe sealant to the steel fittings before making any 

connection. 

BE CAREFUL!

 Ensure all gas connections are snug, but not over tighten!

2. Extend the gas supply system using minimum of ¾” black iron pipe or an approved flexible gas line from existing house 

supply. This can be accomplished by teeing off or tapping into a convenient gas line connection. Install necessary pipe for 

the distance required and then install a manual shut-off valve at the exterior house wall. If pipe is to pass through a foun

-

dation or house wall, make sure to re-seal the area around the pipe with weather sealant.

3. From manual valve, extend gas pipe to the Fire Pit location. 

NOTE:

 If pipe is to be placed in an underground trench, 

check with local codes for required depth and materials needed. 

4. Install a ¾” female x ½” male flared brass fitting to the end of the ¾” black iron pipe.  Be sure to clean the pipe threads 

and use Teflon tape or pipe sealant.  

5. Connect the ½” female flared flex connector from the Fire Pit to the ½” male flared brass fitting secured to the black iron 

pipe. Note: Flare to flare connections do not require Teflon tape or pipe sealant.

IMPORTANT

Installation of Natural or LP gas should be done by a qualified installer, service agency or gas supplier.

The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any   

pressure testing of the system at test pressure testing of the system at test pressures in excess of ½ psig (3.5kPa).

This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any 

pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5kPa)

NOTE: 

LP conversion kits are available in the accessory section of this manual.  When converting a Fire Pit ensure you 

follow the instructions supplied with the conversion kit

.

VENTILATION FOR NON-COMBUSTIBLE ENCLOSURE

Fire pits are subjected to many outdoor elements such as 

rain, snow, wind, heat or cold.  These fire pits have electronic    

components that need to remain dry as possible in order to 

operate properly.  

A minimum of 18 square inches of cross 

ventilation (2 sides) is required to keep the components in 

good working order. 

 Use figure 3 as guide to assist to incor

-

porate proper ventilation.  

NOTE

: Ventilation is not required at 

the bottom and may also be incorporated in the upper portion 

of an enclosure.

Fire Pit 

Enclousure

2”x3” 

Fire Pit

Examples of Cross Ventilation

3 - 2”x3” Slots Each Side

2-  1” x 9” Slots Each Side

Cross Flow  Ventilation 

(Min. 18 Sq. In. Per Side)

Figure 3. Cross Ventilation Example

HIGH ELEVATION INSTALLATION

This appliance is listed for elevations from 0-4500 feet in 

Canada and the U.S.  If elevation exceeds 4500 feet it may be 

necessary to decrease the input rating by changing the exist

-

ing burner orifice to a smaller size.  Input should be reduced 

4% for each 1000 feet beyond the 4500 feet above sea level. 

Check with your local gas utility for assistance in determining 

the proper orifice in your location.  In some cases the heating 

value may already be reduced and downsizing the orifice may 

not be necessary.

Skytech Fire Pits

Summary of Contents for SFRSR19DSI

Page 1: ...tion and Operating Instructions IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE Warning For Outdoor Use Only PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLTION PRECAUTION This fire pit requires a minimum 18 square inches of cross ventilation Failure to provide proper ventilation can void the warranty ...

Page 2: ...5 8 8 A3 B2392 254 8 C D438E 3F 38 58 897 4 4659 958 G377 H C I 4 F234 56673589 38 58 897 4 4659 4 92 54 5 95 6 J F 8FJ 95 2 C 03 2 1 02 2 03 2 01 902 2 0 7 90 A 21 1 6 2 1 0 9 2 61 6 10 7 A 6 1 2 B 1 1 7 03 K L D M K 1L 0 1 1 2 1 03 1 4 5 6 1 7 28 27 2 03 5292 20 032 1 03 1 66 2 9 61 6 1 2 0 02 A 7B 0 0A 0 1 02 A 1529 1 2 0 9 9 9 2 B 1 1 61 6 10 7 C 7 03 2 0 02 A 6 1 02 7 2 0 9 2 01 902 03 1 3 4 ...

Page 3: ...g to Fire Pit 4 Cross Ventilation Requirements 4 Installation Into An Approved Enclosure Requirements 5 Installation of Battery Pack 6 Installation of Lava Rock Media 6 Learning the Remote to Module 7 Operation Initial Start Up 8 Replacement Parts 9 Replacement Parts List 10 Fire Pit Maintenance 11 Trouble Shooting 11 Wiring Diagram 12 Accessory Parts 13 Warranty 14 TABLE OF CONTENTS Skytech Fire ...

Page 4: ...EV 1 6 12 Page 3 Model High Btu s Natural Propane LP Low Btu s Natural Propane LP SFRSR 19DSI 80 000 Btu s 50 000 Btu s SFRSR 25DSI 110 000 Btu s 50 000 Btu s SFRSS 20DSI 80 000 Btu s 50 000 Btu s SFRSS 26DSI 110 000 Btu s 50 000 Btu s Table 2 Btu Specifications NG LP Min Inlet 5 0 WC 11 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures MODEL SFRS19DSI SFRS25DSI SFRSS20DSI SFRSS26DSI MINIMUM IN...

Page 5: ...Pit to the male flared brass fitting secured to the black iron pipe Note Flare to flare connections do not require Teflon tape or pipe sealant IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of the system at...

Page 6: ... fire pit should be stable and solid From the bottom of the control box that houses the gas valve and module it should be a minimum if of 4 inches to the ground level See figure 1 Drainage is critical to ensure that water does not damage and valve components Never install the fire ring system below grade 11 CAUTION A minimum of 18 square inches of cross ventilation 2 sides is required to keep the ...

Page 7: ...nd control system should be tested before the media lava rock is installed NOTE If using optional 120V power adapter AF 4000ADP24 you must use a switch or a breaker that can be turned ON and OFF easily Normal operations are with battery power and nothing else would have to be done INSTALLATION OF BATTERY INTO TRANSMITTER You have one handheld transmitter model RCAF 3 and you will need to install t...

Page 8: ...that the module is ready to receive a transmitter code See fig 10 4 Take the transmitter and press the OFF button You will hear a series of rapid beeps indicating the module has accepted the new code NOTE A maximum of three 3 codes can be programmed to the module After a total of three 3 codes have been pro grammed the memory is full and will not accept any additional codes To clear all codes pres...

Page 9: ...nal 120V power adapter you must turn the switch or breaker ON If using the standard battery pack ensure batteries are installed and the Fire Pit is ready to operate 3 Press the ON button on the handheld transmitter You will hear the ignitor probe sparking light the gas and fire pit will come on WARNING Do not stand over Fire Pit during ignition or operation due to high surface tempera tures NOTE I...

Page 10: ...REV 1 6 12 Page 9 REPLACEMENT PARTS 1 2 4 12 13 14 9 17 8 16 15 ON OFF HI LOW 18 SKYTECH SKYTECH SKYTECH SKYTECH 20 7 6 5 19 Skytech Fire Pits 3 ...

Page 11: ...100 1030 11 DSI Valve Box Assembly not shown 1 ST2 010 1010 12 Stainless DSI Fire Pit Valve Box Only 1 ST3 100 1020 13 Stainless DSI Fire Pit Valve Box Cover Only 1 ST3 100 1021 14 Control Module AF 5000MOD 1 Inside valve box 1 ST3 030 1039 15 AF 4025 DSI Gas Valve 5 0 WC Natural Gas 1 ST2 080 1025 16 1 2 Flex Gas Line 24 inch Length 1 ST3 094 1001 17 Air Shutter Orifice NG 13 Used on 25 26 Fire P...

Page 12: ...t Warn users if the pilot is not successfully ignited in 15 seconds How to Clear Press OFF then ON buttons to re attempt ignition What to Check 1 Ensure gas supply is turned on 2 Ensure that the gas line is purged of air Air is common in the gas line if the appliance has just been installed has been disconnected then re connected to the gas line or if the appliance has been unused for an extended ...

Page 13: ...ng range 8 Make sure that there is not a large metal obstruction between the remote transmitter and the control module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system is in the ON position but does not sense a flame 2 Make sure that the flame sensor electrode is clean Soot buildup will insulate the electrode and...

Page 14: ...ire pits The following accessories are available from your local Skytech dealer distributor Each accessory comes with a separate installation manual Read each instruction thoroughly before installing FCC REQUIREMENTS NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFER ENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO...

Page 15: ... Fire Pits caused by accident misuse abuse or installation error whether performed by a contractor Service Company or owner is not covered by this warranty Modification of the Skytech product will void this warranty IN NO EVENT SHALL SKYTECH BY LIABLE FOR INCIDENTAL AND CONSEQUENTIAL INCLUD ING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRAN...

Reviews: