REV. 11-16-18 Page 10
Round Flat Disc Fire Pits
Key Valve Flange
Non-
Combustible
Wall Material
Non-
Combustible
Wall Material
Key Valve
Primary Gas
Supply
K
ey
Va
lv
e
S
i
de
View
D
e
tai
l
F
ig. 8
Typical installations.
NOTE
: Key valve and flexible gas lines
are supplied. Gas shut-off is not supplied.
Note:
A 1¼” x 2” black iron or galvanized
coupler/nipple (not supplied) can be used
as a spacer between the manual valve
and the valve flange to add additional
support to hold the manual key valve in
place.
Key Valve Flange
Non-
Combustible
Wall Material
Non-
Combustible
Wall Material
Key Valve
Black Iron
Nipple
SECTION
A - MA
TCH LIGHT (MT) INST
ALLA
TION
ON
OFF
Stone Cap
Flat Disc With Spur
Man Made Stone
6x12 Vent
Cement Block Illustration
INSTALLING KEY VALVE
The key valve contents: 1- key valve, 1- key and 1- flange. The valve
requires a 1” round clearance hole in the non-combustible enclosure wall.
See the instructions supplied with the key valve for more specific details.
Note
: Be sure to leak test all fitting before operation. Figures 8 shows an
example of a typical installation.
Key Valve
Gas Supply
Fire Pit Disc
Non-Combustible
Fire Pit Enclousure
Shut-Off
f i r e - p a r t s . c o m