background image

SPECIFICATIONS

Table1.  Fire Pit Dimensions

A

B
C

.875 TYP. (usable flat lip)

*

*

D

Ground Level (Earth)

Figure 1.  Fire Pit Dimensions; refer to Table 1. 

                (Dimensions applicable to round or square pans)

I-MT  REV. 7-23-15  Page 3

Model:

MT Natural Gas (NG)

NG Factory 

Orifice

BTU’s

Natural

FPB-25RBS22MT-N

#22

100,000

FPB-29RBS22MT-N

#22

100,000

FPB-33RBS31MT-N

#08

160,000

FPB-19RBS16MT-N

#31

60,000

FPB-25RBS22MT-N

#22

100,000

FPB-20SBS16MT-N

#31

60,000

FPB-26SBS22MT-N 

#22

100,000

FPB-32SBS31MT-N

#08

160,000

FPB-38SBS36MT-N

#03

183,000

Table 2. Btu Specifications

Pressure

NG

LP

Min. Inlet

3.5” WC

 8.0” WC

Max. Inlet

10.5” WC 13.0” WC

Normal Inlet 7.0” WC

11.0” WC

Table 3. Gas Pressures

Model:

Natural Gas (NG)

A

Pan 

Depth

B  

Min./Max.

Install Opening

C

Inside 

Pa

n

Ground 

Level

E

Side 

Wall

F

Combustible

Ceiling

G

Combustible

Floor

FPB-25RBS22MT-N

2.500”

25.25”/27.5”

23.875”

8”

36”

96”

18”

FPB-29RBS22MT-N

2.500”

30”/31.35”

29”

8”

36”

96”

18”

FPB-33RBS31MT-N

2.500”

34”/35.25”

33”

8”

36”

96”

18”

FPB-19RBS16MT-N

2.750”

19.25/21.5”

19”

8”

36”

96”

18”

FPB-25RBS22MT-N

2.750”

25.25”/27.5”

25”

8”

36”

96”

18”

FPB-20SBS16MT-N

2.750”

20.25”/21.75”

20”

8”

36”

96”

18”

FPB-26SBS22MT-N 

2.750”

26.25”/27.75”

26”

8”

36”

96”

18”

FPB-32SBS31MT-N

2.750”

32.25”/33.75”

32”

8”

36”

96”

18”

FPB-38SBS36MT-N

2.750”

38.25”/39.75”

38”

8”

36”

96”

18”

Disclaimer:

 Btu listings are based on 7.0”WC for Natural Gas and 11.0”WC 

for Liquid Propane (LP) at the burner orifice.  Flex line size and proper gas 

pipe sizing will also affect Btu’s.  As a result your Btu’s may vary slightly from 

Table 2 specifications.

MT Burning Spur Fire Pits

Figure 2. Clearance to Combustibles 

(Not to be used in an enclosed space)

F

E

G

Summary of Contents for firegear Outdoors FPB-19RBS16MT-N

Page 1: ...ral Gas Description FPB 25RBS22MT N 25 Round Stainless Pan with 22 Stainless Spur Burner FPB 29RBS22MT N 29 Round Stainless Pan with 22 Stainless Spur Burner FPB 33RBS31MT N 33 Round Stainless Pan wit...

Page 2: ...this appliance in an enclosed space such as a camper tent car or home WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage pe...

Page 3: ...stion such as fuels contain chemicals known to cause cancer birth defects and or other reproductive harm This warning is issued pursuant to the California Health Safety Code Sec 25249 1 NOTE An exteri...

Page 4: ...in Max Install Opening C Inside Pan D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor FPB 25RBS22MT N 2 500 25 25 27 5 23 875 8 36 96 18 FPB 29RBS22MT N 2 500 30 31 35 29 8 36 96 18...

Page 5: ...at the exterior house wall If pipe is to pass through a foundation or house wall make sure to re seal the area around the pipe with weather sealant 3 The primary gas shut off not supplied will require...

Page 6: ...indoor use 9 This fire pit is designed to have lava rock completely covering the spur burner so that the burner is not visible Do not cover more than 1 above the top of the covered burner When purcha...

Page 7: ...Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied MT Burning Spur Fire Pits Note A 1 x 2 black iron or galvanized coupler nipple not supplied...

Page 8: ...ection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This applia...

Page 9: ...I MT REV 7 23 15 Page 8 MT REPLACEMENT PARTS 1 2 6 MT Burning Spur Fire Pits 3 8 7 5 4 9 10 Drawings are not proportioned O N O F F 11 12 13 14...

Page 10: ...used on 38 Pan B Spur36 4 1 x 2 Blank Cover Plate 1 ST3 100 1030 5 1 2 NPS Brass Nut 1 105 8 6 7 8 Flat Washer Spacer 1 ST3 113 1026 7 1 2 Flex Gas Line 46 inch Length 1 T200 9898 46 8 Air Shutter Or...

Page 11: ...d ON 3 Ensure there is not too much media overtop of burner it can inhibit gas from flowing 4 Check gas pressure Low flame 1 Ensure the base media is at least 1 inch in diameter and top media is no mo...

Page 12: ...REV 7 23 15 Page 11 MT Burning Spur Fire Pits FOR TECHNICAL SERVICE CALL Firegear Outdoors 9230 Conservation Way Fort Wayne IN 46809 For Sales 888 672 8929 WEB SITE www firegearoutdoors com 855 498 8...

Page 13: ...Pit Pan Primary Gas Line Expanded View of Match Throw Fire Pit T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings E...

Page 14: ...mpound Repeat the testing process and replace the gas line if the soap solution continues to bubble Pipe Fitting Precautions CAUTION Failure to follow the procedures below could result in fire of loss...

Reviews: