ELECTRONIC SPARK SYSTEM CHECK

• 

Slide the 3-position button on the remote receiver to the 

ON

 position.  The spark electrode should begin sparking to ignite the pilot.  

After the pilot flame is lit, the main gas valve should open and the main gas flame should ignite.

• 

Slide the button to 

OFF

.  The main gas flame and pilot flame should both extinguish.

• 

Slide the button to 

REMOTE

, then press the 

ON

 button on the transmitter to change the system to on.  The spark electrode should 

begin sparking to ignite the pilot.  After the pilot is lit, the main gas valve should open and the main gas flame should ignite.

LEARNING TRANSMITTER TO RECEIVER

• 

• 

Each transmitter uses a unique security code.  It will be necessary to press the LEARN button on the receiver to accept the trans-

mitter security code upon initial use, if batteries are replaced, or if a replacement transmitter is purchased from your dealer or the 

factory.  In order for the receiver to accept the transmitter security code, be sure the slide button on the receiver is in the REMOTE 

position; the receiver will not LEARN if the slide switch is in the ON or OFF position.  The LEARN button in located on the front face 

of the receiver; inside the small hole labeled LEARN.  Using a small screwdriver or end of a paperclip gently press and release 

the black LEARN button inside the hole.  When you release the LEARN button the receiver will emit an audible “beep”.  After the 

receiver emits the beep press ANY transmitter button and release.  The receiver will emit several beeps indicating that the transmit-

ter’s code has been accepted into the receiver.

WIRING ELECTRONIC SPARK IGNITIONS

ELECTRONIC MODULE

TR

TH

REMOTE

RECEIVER

neutral wire

24VAC

hot wire

120VAC

110/24VAC

Transformer

The remote control receiver can be connected, in series, to a 24VAC 

transformer to the TR (transformer) terminal on the ELECTRONIC 

MODULE.  Connect the hot wire from the 24VAC transformer to either 

of the wire terminals on the remote receiver.  Connect another wire be-

tween the other receiver wire terminal and the TH (thermostat) terminal 

on the ELECTRONIC MODULE.

WIRING INSTRUCTIONS

A qualified electrician should install the remote control system.

TERMINAL BLOCK

ON MILLIVOLT

GAS VALVES

TH

TP

TP

TH

THERMOPILE/

PILOT LIGHT

REMOTE

RECEIVER

• 

Connect one wire from the remote receiver to the TH terminal on the gas 

valve.

• 

Connect the other wire from the remote receiver to the TH/TP terminal on 

the gas valve.

WIRING MILLIVOLT VALVES

MILLIVOLT SYSTEM CHECK

• 

Ensure that the pilot flame is lit.

• 

Slide the 3-position button on the remote receiver to the 

ON

 position.  The main gas flame (i.e., the fire)   

should ignite. 

• 

Slide the button to 

OFF

.  The main flame should extinguish (the pilot flame will remain on).

• 

Slide the button to 

REMOTE

, then press the 

ON

 button on the transmitter to change the system to on. The main 

gas flame should ignite.

Skytech 1001-A

REV. 11-8-16 Page 3

Summary of Contents for 1001-A

Page 1: ... the transmitter It is designed to be used with milivolt gas valves as a dry contact switch ON OFF FRONT BACK SIGNAL LIGHT ON OFF BUTTONS BATTERY COMPARTMENT RECEIVER Install the 4 AA size batteries supplied with the unit It is recommended that ALKALINE batteries always be used for this product Be sure the batteries are installed with the and ends facing the correct direction ON will manually turn...

Page 2: ... fireplace hearth or under the fire place behind the control access panel Use the wires attached to the remote receiver to connect to the gas valve or the electric module piggyback connectors have both male female terminals for flexibility Be sure that the connectors do not touch each other or other bare metal surfaces this will cause the appliance to turn on The connectors may be wrapped with ele...

Page 3: ...lease the LEARN button the receiver will emit an audible beep After the receiver emits the beep press ANY transmitter button and release The receiver will emit several beeps indicating that the transmit ter s code has been accepted into the receiver WIRING ELECTRONIC SPARK IGNITIONS ELECTRONIC MODULE TR TH REMOTE RECEIVER neutral wire 24VAC hot wire 120VAC 110 24VAC Transformer The remote control ...

Page 4: ...lem may be with either the fireplace itself or with the remote Review the fireplace manufacturer s operation manual to make sure all connections are properly made Then check the operation of the remote in the following manner Make sure all batteries are correctly installed in the transmitter and receiver Also check that the batteries are fully charged Check batteries in transmitter to make sure co...

Reviews: