6
TABLE 01
CHARACTERISTICS
UNIT
ABN-HD-N
Average Produc
ti
on
kg/h
up to 400
Voltage
V
220
Frequency Hz
60
Power Rati
ng
CV
0,5
Consump
ti
on
kW/h
0,37
Height
mm
560
Width
mm
580
Depth
mm
250
Net Weight
kg
28,5
Shipping Weight
kg
35
1.3 Technical Characteris
ti
cs
2.1.2 Electrical Installa
ti
on
The equipment has been designed to operate 220 Volts. When you receive the equipment
check the voltage indicated on the cord label.
The power plug has 3 pins the middle pin is the ground. All the 3 pins must be properly
connected.
2. Installa
ti
on and Pre Opera
ti
on
2.1 Installa
ti
on
2.1.1 Placing
The equipment must be placed on to a levelled stable surface approximately 850 mm high.
19
6. Maintenance
Maintenance must be considered a set of procedures with the purpose to keep the
equipment best opera
ti
ng condi
ti
ons, therefore increasing the equipment life and safety.
* Cleaning – check item 3 5 Cleaning.
* Wiring - Check all wires regarding deteriorate conditions as well as all electric contacts
(terminals) regarding ti
ghtening and corrosion.
* Contacts – ON/OFF switch, emergency butt
on, reset bu
tt
on, electronic circuits etc,
check the equipment in order to assure that all components are correctly working and the
equipment opera
ti
on is normal.
* Installa
ti
on – make sure the installa
tion followed item 2.1 instructi
ons.
1 - Each month check:
- Check the electrical installa
ti
on;
- Measure the voltage at the socket;
- Measure the working current and match it with the nominal current;
- Check the
ti
ghtening of all electric terminals to avoid bad contacts;
- Check electric motor sha
ft
clearance;
- Check the wiring for overeati
ng, insula
ti
on failures and mechanical damages;
2 - Each three month checks:
- Check electrical components such as ON/OFF switch, emergency butt
on, reset bu
tt
on,
electronic electric circuits, overea
ti
ng, insula
ti
on failings, or mechanical damages;
- Check bearings clearances;
- Check retainers, O’rings, V’rings and other seals.