Skylark BT-905 Use And Maintenance Book Download Page 10

10

- Warranty - One year limited warranty.
- Durable.
The product or its components cannot be used for usages different to the ones specified in the present
manual.

PRESCRIPTIONS

Plug in device only into a properly installed socket.

Do not dip it into water! Before cleaning always pull out plug from the socket.

When removing lead connectors, grasping them by the plug D, not the cord F.
Don’t expose to excessive amounts of moisture. Don’t leave in direct sunlight for extended periods of
time.
Don’t drop or hit against other objects. Treat is as you would other sophisticated electronic devices
such as a calculator or recorder.

Flex 

has to be examined regularly for damages.

Do not use device if damages are detected. Go to an expert electrician.

Avoid precarious repairs. Repairs shall be carried out with original spare parts only, which

shall be installed according to the intended use.

UNPACKING

Always remember that packing elements (paper, cellophane, stitches, adhesive tape, etc.)

can cut and/or hurt if they are not carefully handled.

They shall be removed with adequate means and shall not be left at the mercy of irresponsible

persons; the same is valid for tools used to remove packages (scissors, knives, etc.).

After opening the packages, first of all it is necessary to check all pieces and parts composing the
product. Check that they are all present and in perfect conditions.

GETTING YOURSELF READY FOR TESTING

To be sure your test results are accurate you must follow the guidelines listed below as exactily as
possible to be sure that  you will consistently obtain the most valid and reliable results possible
with your BT-905 instrument.
1. 

Meals. Wait at least 5 hours after a meal before performing the test.

2. 

Hydration. Do not consume large amounts of water just prior to testing. (Some medications-

particularly diuretics-may also affect test results).
3. 

Coffee. Do not drink coffee for 4 hours before testing. Coffee is a diuretic and may affect the

hydration level of your body.
4. 

Alcohol. Do not drink alcoholic beverages for 24 hours pripor to testing. Alcohol is a diuretic.

In your bloodstream, it also conducts electricity in such a way as to interfere with an accurate test.
5. 

Exercise.  Don  not  test  your  body  composition  for  a  least  12  hours  after  exercise.  (This  is

becauseexercise has a significant effect on your body’s water content).
6. 

Weight. Check your weight on a reliable pair of scales immediately before testing. This is

particularly important for those who tend to be quite lean. The scientific formulas used to accurately
calculate your percents of lean and fat are dependent on an accurate scale weight. Even using yesterday’s
weight is not close enough to assure a valid test.

Just before the test cleanse your skin using a washcloth with soap and water, cleanse the areas where
you  will  be  placing  the  sensor  pads  G.  Scrub  the  areas  until  the  skin  becomes  pink  but  not  sor  or
irritated. This  will  remove  all  dead  skin,  perspiration,  and  any  excess  oils  that  could  prevent  good
contact with the sensor pads G. Dry the skin with a clean cloth.

Summary of Contents for BT-905

Page 1: ...tamente questo manuale prima di utilizzare il prodotto ATTENTION The operators must carefully read and completely understand the present manual before using the product ATENCI N Los operadores tienen...

Page 2: ...2...

Page 3: ...ni vitali ecc sia la massa organica che quella adiposa contengono acqua Un giusto bilanciamento tra la quantit di massa organica e adiposa riveste una grande importanza per mantenere in buona salute e...

Page 4: ...parazione precaria Le riparazioni vanno effettuate esclusivamente con ricambi originali che vanno installati secondo l uso previsto DISIMBALLO Rammentiamo che gli elementi dell imballo carta cellophan...

Page 5: ...su una bilancia estremamente precisa Utilizzare il peso misurato anche solo il giorno precedente non garanzia per un risultato preciso e accurato del test Subito prima di procedere al test pulire la c...

Page 6: ...tta di preferenza sul nudo pavimento o su di un tavolo Durante l esecuzione del test le braccia non devono toccare il corpo Le braccia devono giacere lungo i fianchi e le palme piatte sul pavimento ad...

Page 7: ...lorie necessarie all esercizio fisico Il metabolismo basale strettamente correlato alla quantit di tessuto muscolare presente nel corpo Maggiore la quantit di tessuto muscolare maggiore sar il valore...

Page 8: ...parecchio non sufficientemente forte per essere letto e interpretato a Controllare gli elettrodi G Assicurarsi che siano ben applicati alla superficie cutanea ricordarsi di pulire con attenzione la cu...

Page 9: ...the lean and fat tissue weights are properly balanced Now the BT 905 will help you to manage your nutrition fitness and weight It not only can tell if you are at the right weight but also tell you whe...

Page 10: ...est results are accurate you must follow the guidelines listed below as exactily as possible to be sure that you will consistently obtain the most valid and reliable results possible with your BT 905...

Page 11: ...t back The edge of the sensor pad should just touch the crease The pad on the foot should be applied just behind the place where the big toe and the first toe join The position for the sensor pad at t...

Page 12: ...seconds 1 Turn machine ON B 2 Warm up the unit for at least 10 minutes before testing 3 Press C E key pad to select units of measure Press 0 for the english units or 1 for the metric units 4 Press Ent...

Page 13: ...match TARGET FAT Target percent fat is a valuewhich represents a normal percent for your sex and age It does not necessarily represent the best percent fat for you For example very fit individuals of...

Page 14: ...e most stringent requirements regarding the selection of quality manufacturing materials and also the final control The product has a 12 month warranty valid from the date it is delivered by RAM Durin...