SECTION 2, Page 3
SJKB Battery Powered
1. EMERGENCY TURRET ROTATING MECHANISM
- This mechanism is located on the rotation gear under
the turret. Using a 7/8" 6-point socket with ratchet to
rotate the turret back to center. NOTE: On European
models a 7/8" 6-point ratcheting wrench (SKYJACK
#701517) is located inside the hydraulic/electric cabinet.
Base Controls - Mechanical
Emergency Turret Rotating Mechanism
Figure 2-3A. Emergency Turret Rotating Mechanism
(SJKB-33N)
Figure 2-3B. Emergency Turret Rotating Mechanism
(SJKB-33i, 33C, 40i, 40C)
350 Amp Battery Connectors
Figure 2-2A. 350 Amp Battery Connectors
(SJKB-33N)
1. 350 AMP BATTERY CONNECTORS
1. 350 AMP BATTERY CONNECTOR - These
connectors, located adjacent to the battery charger,
disconnects the batteries and all power to both control
stations in the event of an emergency and for work
platform shut down. This connection MUST be made to
operate any control on either control station. The battery
charger works independently of this connection and the
batteries may still be charged while these connectors
are separated.
1
1
MA33N202
MA33N203
Figure 2-2B. 350 Amp Battery Connectors
(SJKB-33i, 33C, 40i, 40C)
1
Mawb203
1. EMERGENCY TURRET ROTATING MECHANISM
1
Mawb204
SECTION 2, Page 6
SJKB Battery Powered
WARNING
WARNING
1.
EMERGENCY STOP BUTTON
2.
BOOM UP/DOWN TOGGLE SWITCH
3.
RISER UP/DOWN TOGGLE SWITCH
4.
JIB UP/DOWN TOGGLE SWITCH
5.
TURRET ROTATE TOGGLE SWITCH
6.
BOOM EXTEND/RETRACT TOGGLE
SWITCH
7.
PLATFORM LEVELING TOGGLE SWITCH
8.
PLATFORM ROTATE TOGGLE SWITCH
9.
BOOM SPEED CONTROL ROTARY SWITCH
10.
DRIVE/STEER CONTROLLER
11.
HORN PUSH-BUTTON
12.
TILT SENSOR INDICATOR LIGHT
13.
FUNCTION ENABLE LIGHT
Operator’s Control Console
Figure 2-8. Operator’s Control Console and Label
1
Platform Controls - Electrical
Foot Switch
Figure 2-7. Foot Switch
1. FOOT SWITCH
1. FOOT SWITCH - The foot switch is located on the
platform. When the foot switch is depressed and held,
power is brought to the controls on the operator’s control
console. When the foot switch is released, the controls
on the operator’s control console are cutout.
IMPORTANT NOTE
The foot switch MUST be depressed and held to use
any control on the operator’s control console.
Before releasing the foot switch, the controllers should
be returned to the neutral position. Work platform
motion will stop when the foot switch is released.
When driving and foot switch is released, parking
brake engages instantly.
OPERATOR’S CONTROL CONSOLE - This metal
control station is located at the front of the platform. It
contains the following controls:
IMPORTANT NOTE
The foot switch MUST be depressed and held to use
any control on the operator’s control console.
Refer to Operating Procedures for detailed
instructions on operating these controls.
1.
EMERGENCY STOP BUTTON - This red
mushroom-shaped button is designed to cut power to
the platform controls when struck in the event of an
emergency or at work platform shutdown. To restore
power, simply pull button out.
MA33N209
13
12
11
10
9
8
7
6
5
4
3
2
1
MA33N212
Depressing the Emergency Stop Button instantly
engages the parking brakes.