175
SJ30AJE, SJ30ARJE
196274AF
Base
Section 5 – Procedures
Flash
Code
Displayed
on
MDI
Probabable
Cause
Remedy
0XA89
PUMP
VACC
NOT
OK
The
pump
accelator
value
is
higher
than
the
minmum
value
recorded,
and
the
lift/
lower
switches
are
open.
1.
Check
wiring.
2.
Aquire
joystick
VACC.
3.
Replace
joystick/
switch.
Replace
controller
0XA92
CURRENT
GAIN
Internal
Controller
check
1.
Cycle
keyswitch
2.
Factory
reset
(Clear
Eeprom)
3.
Replace
controller.
0XA96
ANALOG
INPUT
Analog
to
digital
failure
Cause:
This
alarm
occurs
when
the
A/D
conversion
of
the
analog
inputs
gives
frozen
value,
on
all
of
the
converted
signals,
for
more
than
400msec.
The
goal
of
this
diagnosis
is
to
detect
a
failure
of
the
A/D
converter
or
a
problem
in
the
code
flow
that
omits
the
refreshing
of
the
analog
signal
conversion.
Troubleshooting:
If
the
problem
occurs
permanently
it
is
necessary
to
Replace
controller
0XA99
SLIP
PROFILE
Error
on
the
parameters
of
the
slip
profile
setting.
1.
Cycle
keyswitch
2.
Factory
reset
(Clear
Eeprom)
3.
Replace
controller.
ZAPI MDI-CAN Controller Master Codes (continued)
Summary of Contents for SJ30AJE
Page 1: ...SERVICE MANUAL ARTICULATING BOOM 196274AF November 2018 ANSI CSA CE AS KC SJ30AJE SJ30ARJE ...
Page 4: ...4 SJ30AJE SJ30ARJE 196274AF Notes ...
Page 10: ...10 SJ30AJE SJ30ARJE 196274AF 5 7 1 Lubrication 188 ...
Page 45: ...45 SJ30AJE SJ30ARJE 196274AF Section 3 System Component Identification and Schematics ...
Page 68: ...A B C D E F G H V Z Y X W 68 SJ30AJE SJ30ARJE 196274AF ...
Page 128: ...128 SJ30AJE SJ30ARJE 196274AF Notes ...
Page 189: ......
Page 190: ...www skyjack com ...