![Skyjack SJ30AJE Service Manual Download Page 172](http://html1.mh-extra.com/html/skyjack/sj30aje/sj30aje_service-manual_1290406172.webp)
172
SJ30AJE, SJ30ARJE
196274AF
Section 5 – Procedures
Base
Flash
Code
Displayed
on
MDI
Probabable
Cause
Remedy
0XA62
TH.
PROTECTION
Controller
High
temp
alarm,
if
high
temp
is
not
real
proceed
to
remedy
Cause:
This
alarm
occurs
when
the
temperature
of
the
base
plate
is
higher
than
85°.
Then
the
maximum
current
decreases
proportionally
with
the
temperature
increases
from
85°
up
to
105°.
At
105°
the
Current
is
limited
to
0
Amps.
Troubleshooting:
It
is
necessary
to
improve
the
controller
cooling.
In
case
of
thermal
dissipation
realised
with
the
controller
base
plate
installed
on
chassis
it
is
important
the
thickness
of
frame
and
the
planarity
and
roughness
of
its
surface.
If
the
alarm
is
signalled
when
the
controller
is
cold,
the
possible
reasons
are
a
thermal
sensor
failure
or
a
failure
in
the
logic
card.
In
this
case,
it
is
necessary
to
replace
the
controller.
0XA65
MOTOR
TEMPERAT.
Motor
temp
high.
Cause:
This
warning
occurs
when
the
temperature
sensor
has
overtaken
the
threshold
of
150°
Troubleshooting:
Check
the
thermal
sensor
inside
the
motor
(use
the
MOTOR
TEMPERATURE
reading
in
the
TESTER
menu);
check
the
sensor
ohmic
value
and
the
sensor
wiring.
If
the
sensor
is
OK,
improve
the
cooling
of
the
motor.
If
the
warning
is
present
when
the
motor
is
cool,
then
the
problem
is
inside
the
controller.
Replace
controller.
0XA65
BATTERY
LOW
Battery
is
<=
10%
when
the
parameter
BATTERY
CHECK
is
set
to
0.
Check
that
the
controller
SET
BATTERY
parameter
value
matches
the
battery
normal
voltage.
Check
that
the
TESTER
MENU/
BATTERY
VOLTAGE
parameter
shows
same
value
as
the
battery
voltage
measured
with
a
volt
meter.
If
it
does
not
match,
then
do
a
"ADJUST
BATTERY"
function.
If
above
OK,
Replace
controller.
05X67
SENS
MOT
TEMP
KO
Motor
temp
sensor
damaged
Cause:
The
output
of
the
motor
thermal
sensor
is
out
of
range.
Troubleshooting:
Check
the
sensor
ohm
value
(at
20C
the
Sensor
should
read
approx
600
Ohms)
and
the
sensor
wiring.
If
the
sensor
is
OK,
then
the
problem
is
inside
the
controller
Replace
controller.
05X68
WAITING
FOR
NODE
Alarm
condition
active.
Waiting
for
communication
between
controllers
1.
Cycle
keyswitch
2.Check
that
both
nodes
are
present
on
the
network
using
Can
Console.
3.
Check
wiring
to
the
missing
controller.
If
everything
OK.
Replace
controller
with
node
missing.
ZAPI MDI-CAN Controller Master Codes (continued)
Summary of Contents for SJ30AJE
Page 1: ...SERVICE MANUAL ARTICULATING BOOM 196274AF November 2018 ANSI CSA CE AS KC SJ30AJE SJ30ARJE ...
Page 4: ...4 SJ30AJE SJ30ARJE 196274AF Notes ...
Page 10: ...10 SJ30AJE SJ30ARJE 196274AF 5 7 1 Lubrication 188 ...
Page 45: ...45 SJ30AJE SJ30ARJE 196274AF Section 3 System Component Identification and Schematics ...
Page 68: ...A B C D E F G H V Z Y X W 68 SJ30AJE SJ30ARJE 196274AF ...
Page 128: ...128 SJ30AJE SJ30ARJE 196274AF Notes ...
Page 189: ......
Page 190: ...www skyjack com ...