TM
Page 36
December 2007
SJ 46A & SJ 46AJ
Function Tests
Section 2 - Operation
NOTE
To conserve battery power, test each
function through a partial cycle.
3. On base control console, pull out “
”
emergency stop button.
4. O n b a s e c o n t r o l c o n s o l e , t u r n
base/off/platform key switch to “
”
platform position.
5. Select “
” emergency power position
from start/function enable/emergency
power switch and activate each boom
function.
Result:
All selected functions should
operate.
6. Turn base/off/platform key switch to “
”
base position.
7. Select “
” emergency power position
from start/function enable/emergency
power switch and activate each boom
function.
Result:
All selected functions should
operate.
NOTE
The emergency power unit has two-minute
duty cycle.
Test Base/Off/Platform Switch
•
1. Ensure both “
” emergency stop
buttons are pulled out.
2. Start engine.
3. On base control console, turn base/off/
platform key switch to “
” off position.
Result:
Engine should shut down and
aerial platform functions should not
operate.
4. On base control console, turn base/off/
platform key switch to “
” platform
position.
wARNiNG
Ensure that you maintain three points of
contact to mount/dismount platform.
5. Enter platform and close gate.
6. On platform control console, select “
”
on position from engine enable switch.
Emergency
Stop
Base Control Console
Base/Off/Platform Key
Switch
Start/Function Enable/
Emergency Power
Switch