SJ 86T
December 2007
Page 43
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
contained in this operating manual and on the MEWP.
F
AMILIARIZA
TION
11. Press the sensor bar for more than 1
second and then release.
Result:
The function will stop and the
audible/visual alarm should activate
immediately and stay on after the bar is
released. The engine should shut down
after 1 second. The reset button should
illuminate. The engine fault and glow plug
indicator lights should illuminate.
12. Start the engine.
13. Activate any platform function (i.e. lift/
extend/rotate).
14. Press the sensor bar for less than 1
second and then release.
Result:
The function will stop while the
bar is being pressed and motion will
resume when the bar is released. The
audible/visual alarm should activate
while the bar is being pressed and turn
off after being released. The reset button
should illuminate as soon as the sensor
bar is pressed and turn off when the bar
is released.
15. Press the sensor bar for more than 1
second and then release.
Result:
The function will stop and the
audible/visual alarm should activate
immediately and stay on after the bar is
released. The engine should shut down
after 1 second. The reset button should
illuminate. The engine fault and glow plug
indicator lights should illuminate.
16. While the audible/visual alarm is sounding,
verify that the LED strobe light is also
active.
Horn
Emergency Power
Switch
Emergency Stop
Engine Start/On/
Off Switch
Platform Leveling
Override Switch
Drive/Steer
Controller
Reset Button
Section 2 - Familiarization
Function Tests