Configuration Selection
In the normal operational mode the system is programmed to remember the last configuration selected. Each time
the system is powered up it will automatically default to that configuration. Only when the crane is rigged differently
must a new configuration be selected. Use the following procedure to select the crane configuration.
Note: When selecting configurations allowed on outriggers, all beams must be equally extended; all fully
retracted, intermediate extended, or fully extended.
Depending on how the crane is equipped or which selections have been made, some screens shown may not
appear or may not appear as illustrated. The system cannot be programmed for configurations not allowed
by the capacity charts listed in the Crane Rating Manual.
Figure 1−71
Carrier Selection
1.
From the normal working screen press the CRANE SETUP button. The normal working screen will change and
graphically display the carrier options. Press the corresponding configuration selection button to select the
desired carrier configuration. If rigging is desired, refer to To Select Rigging/Travel Mode" found later in this
Section of the Operator’s Manual.
WARNING
The Microguard 534 is not operational when in the RIGGING/TRAVEL Mode. Return the Microguard 534
to normal operation before operating the crane.