background image

SkyAzúl,

 

Equipment

 

Solutions

                                     

www.skyazul.com

                                        

301

371

6126

  

Information

 

display

 

shows

 

letter

 

f:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEXT: "f = 1" 

Main Boom angle below permitted 
minimum. LMI 'Cut-off'

 

TEXT: 

"e= 

3” 

Slewing Angle – Superstructure outside 
defined Arc permitted by Operation Code 
entered into CPU

 

Raise or lower Main Boom Angle 
OR Luffing Jib Angle

 

Return to the defined arc as laid 
down in the load chart

 

NO

 

YES

 

YES

 

NO

 

Raise Main Boom to within 
permitted angle range

 

YES

 

Contact SkyAzul  301-748-6057

 

NO

 

TEXT: 

"e= 

2” 

Angle of Luffing Jib outside permitted 
range

 

          20

Summary of Contents for Krupp EKS 83

Page 1: ...Krupp EKS 83 Service Manual...

Page 2: ......

Page 3: ...y information which is protected by copyright and all rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of...

Page 4: ......

Page 5: ...tiometer 8 LMI Transmitter for Pressure Transducers 8 Selection of lifting capacity chart 9 Selection of lifting capacity tables 9 Calculation of the radius 9 Calculation of the reference value 9 Calc...

Page 6: ...301 371 6126 Information display shows letter c 16 Information display shows letter d 17 Information display shows letter e 19 Information display shows letter f 20 Information display shows letter g...

Page 7: ...SkyAz l Equipment Solutions www skyazul com 301 371 6126 EKS Load Moment Indicator The combined Console and Central Unit 3...

Page 8: ...ngle potentiometer and data transmitter for angle and length 5 Pressure sensor on derricking cylinder 6 Display unit on right hand side of turntable 7 Data transmitter for pressure sensor on right han...

Page 9: ...own is for a GMK407 The position of components in other models may vary and some items might not be fitted 1 Plug in module lOA fuses FI F1 8 2 Plug in module 9 5A with LMI shutdown circuit relay K1 3...

Page 10: ...surface pressure in derricking cylinder in bar h h k No function 5 Warning light shutdown 6 Release button 7 Switch for setting operating mode SLI code 8 Switch for setting reeving mode 9 9 SLI brief...

Page 11: ...ith potentiometer for length telescope sections III and IV 2 Cable drum with potentiometer for length telescope sections I and II 3 Boom unit with angle measurement and data transmitter for angle and...

Page 12: ...rum Potentiometer 1 Using a screwdriver to set the Length Potentiometer to the anti clockwise position with the Boom fully retracted LMI Transmitter for Pressure Transducers 2 Data Transmitter Annular...

Page 13: ...he inherent moment of the boom the actual load is calculated taking into account the reeving configuration set on the central unit Warning and shutdown in case of overload Reference value and calculat...

Page 14: ...ssed current via the common dual line data bus to the central unit Transmitter Boards All transmitter Boards fitted on a machine are the same part number The system each board is monitoring is identif...

Page 15: ...Cut Ofr and Status display will show a code for most transmitter failures it is prefixed with d Note On a number of models a prefix of g will represent certain transmitters i e machines with 4 telesc...

Page 16: ...is dialed into the 2x Reeving Switches Fault Diagnosis Flow Charts No Buzzer or Displays SU inoperative No buzzer signal No displays dark Power supply switched off Fuse F1 8 plug in module 10A blown F...

Page 17: ...Overload Call up SLI fault code Select displayed letter using information switch SLI displays letters a k and numbers 1 8 Leave overload range Press SLI release button See corrective action given on...

Page 18: ...Non authorized reeving mode selected TEXT a 8 Selected operating mode code not possible Central unit faulty Call SkyAzul 301 228 6086 Select correct operating mode Press LMI release button S1 YES YES...

Page 19: ...ct country set for Rating calibrated into CPU 75 85 etc Central unit faulty Call SkyAzul 301 228 6086 a Customer Options Not registering with CPU OR b Telescope section No 1 not locked check lock syst...

Page 20: ...section 2 YES NO NO NO TEXT c 3 Telescope section 3 not locked Lock inspect locking mechanism of tele section 3 YES NO TEXT c 4 Telescope section 4 not locked Lock inspect locking mechanism of tele s...

Page 21: ...s pull central unit out of Instrument panel replace fuse F2 1 25 A Fuse blown again Short circuit in the system Call SkyAzul YES TEXT d 3 Data transmitter Length Telescope sections 1 1 and IV 1 Fuse b...

Page 22: ...Solutions www skyazul com 301 371 6126 Note When replacing Transmitter Boards ensure the Link wires are transferred to the same position on the new board Switch connections 10 17 are only used on old...

Page 23: ...TEXT e 2 Shutdown as radius too large for load Extend telescope sections Compare measured length with the lengths in the lifting capacity table Observe the change on the status display during telesco...

Page 24: ...3 Slewing Angle Superstructure outside defined Arc permitted by Operation Code entered into CPU Raise or lower Main Boom Angle OR Luffing Jib Angle Return to the defined arc as laid down in the load c...

Page 25: ...ect connections across WI W2 or W3 if they are required NO Fit or Refit Link wires as per Transmitter board description Pages 8 9 YES 24 volts on Data bus of Transmitter board Terminals 1 2 Fit or Ref...

Page 26: ...owing voltages present between connections 4 7 With section fully retracted 4 7 0 volt With section fully extended 4 7 2 volt NO With boom fully retracted Adjust Potentiometer to the Zero position ful...

Page 27: ...er Error Code Text other than those described in this manual contact SkyAzul service with the displayed code the Operation Reeving configuration dialed into the Console and a full description of the a...

Page 28: ......

Page 29: ......

Page 30: ...SkyAz l Equipment Solutions www skyazul com 301 371 6126 SkyAz l Inc 16 Walnut Street Middletown MD 21769 Phone 301 371 6126 Fax 301 371 0029 info skyazul com www skyazul com...

Reviews: