Sky Microwave FCT-31A User Manual Download Page 1

 

MULTI-FUNCTIONAL 

HOUSE ALARM SYSTEM 

 

FCT-31A  

 
 

USER MANUAL 

 

 

 

Ver: 1.0 

Summary of Contents for FCT-31A

Page 1: ...MULTI FUNCTIONAL HOUSE ALARM SYSTEM FCT 31A USER MANUAL Ver 1 0 ...

Page 2: ...rm device is used in all GSM networks This system is dedicated to serve home user It mainly focuses on the protection of houses and premises Before operating the terminal please read this manual thoroughly and retain it for future reference in order to get the best service from the terminal and us 1 ...

Page 3: ...TIONS 9 5 1 SMS 10 5 2 PHONE BOOK 12 5 3 CALL LOG 14 5 4 PHONE SETUP 15 5 5 ALARM SETUP 17 6 ALARM OPERATIONS 19 6 1 SET UP ALARM 19 6 2 SET UP LOCAL ALARM 20 6 3 SET UP UNARM 21 6 4 ALERT OPERATION 21 6 5 SOS ALERT 23 7 REPORT FUNCTION 24 7 1 CHILD REPORT 7 2 WORK RECORDING APPENDIX 25 1 SET UP RF CODE 25 2 TEST DETECTORS AND REMOTE CONTROLLERS 26 3 DETECTORS 26 2 ...

Page 4: ...templates pre setup and fast sending Z Phone book function Editing Query Storing Dialing Z Incoming call and SMS limited Black list and white list Z Reporting function Child report Work recording Z SMS alarming and unarming function Z Password supported Z Alarm and Alert Delay Z Backup battery Power supply protection Z All defense and Partial defense Z Guard against theft fire gas door etc Z SOS I...

Page 5: ...dity 20 95 Z Power supply Input AC 110 240V Outup DC7 5 1 5A DC12V 1A optional Z Back up battery Lithium Polymer 600 mAh 3 7V Z Weight Package weight 1 8Kg pcs Z Package size mm 325 310 72 Accessories Standard Package Quantity Main Unit 1 GSM Antenna 2 Remote Control 3 Door window magnetic sensor 2 Infrared Sensor PIR H 1 Siren 1 Power adaptor 1 Backup battery 1 Optional Detector Quantity Smoke De...

Page 6: ...ng light becomes vague 2 INSTALLATION NOTICE Z The terminal should be installed at a place with strong and stable GSM network Z The terminal should never be put together with objects that might bring strong electromagnetic interference Z The distance between the main terminal and each wireless sensor must be no longer than 100m Z The terminal should be installed at a suitable place avoiding dusts ...

Page 7: ...and the Siren 4 Plug the power adaptor with a proper AC power supply Insert the DC output port into the power supply port on the main terminal 5 Confirm the installation is done properly and turn the terminal on by switch Check whether the status indicator is working properly Installation of the Detectors Please refer to the Appendix ON OFF Up side down NO Power Supply Factory use only 6 ...

Page 8: ...ition Left Right direction key check dialed numbers max 20 review the number and name by or key MENU Function switch in submenu Press it to enter into the MENU OK Select in Menu operation Press it to enter the Phone Book EXIT Cancel in Menu operation Press it to enter into SMS Menu setup All or Local Alarmed Mode Unarm the system Ask for emergent helps Press it to enter the SMS templates 7 ...

Page 9: ...med Unread SMS Power supplied by AC Black list activated Battery status While list activated Volume level Siren warning Input Method Number press Numeral state press Number keys Letter Capital press state Input related letter Lowercase press state Input related letter Blank press key Character On state press 0 switch to character input Delete Press key to delete the Number or letter before cursor ...

Page 10: ...ng call limitation Black list When Black list function is activated LCD display 20 phone numbers in the Black list book are refused calls or SMS automatically White list When white list is activated LCD display 20 phone numbers only in the white list book can be received call or SMS The other numbers that are not in the white list will be refused automatically 5 MENU OPERATIONS On standby mode pre...

Page 11: ... FULL display in LCD SMS Receive limit Black list White list Refer to Incoming call limitation If the Inbox is full you may not receive any new SMS 5 1 2 Send SMS If you want to send a new SMS Press MENU 1 SMS OK 4 Creat SMS Start to edit a new SMS New SMS can be saved in Draft box before you send it When you have sent the SMS successfully it will be saved in Sent Items If you want to send a saved...

Page 12: ...ally 1 SMS OK 2 Sent items OK MENU Del All Delete all the SMS in Sent Items View View the content of the selected SMS View OK MENU Call Send Edit Draft Drafts are stored in the terminal 3 items at most It renews automatically 1 SMS OK 3 Draft OK View Menu Del All Delete all the drafts in Draft Box View OK MENU Edit Send View OK MENU Edit OK MENU send Clear Save Create SMS 1 SMS OK 4 Creat SMS OK S...

Page 13: ... Delete all templates MENU Edit OK MENU Clear Delete the input contents OK input or re edit contents Of Templates OK Save OK NOTE In edit state press to move Cursor 5 2 Phone Book In this Menu you can query phone number and edit your phone book 1 Name Query 2 Location Query ation Query 3 Add Entry 3 Add Entry 4 Contacts Limit 4 Contacts Limit MENU 2 Phone Book OK 5 2 1 Name Query 1 Name Query ok i...

Page 14: ...tive Black List display 2 Off OK Deactivate Black List disappear 3 Edit BL OK MENU Delete Delete All Add New View Edit new Num OK 2 White list OK 1 On OK Active White List display 2 Off OK Deactivate Black List disappear 3 Edit WL OK MENU Delete Delete All Add New View Edit new Num OK Edit Blacklist and White list from Call Log or Add Entry You may add numbers to Blacklist White list from Missed c...

Page 15: ...you will need to wait for a while until you could check the Phone Book normally To make a call from MENU you should pick up handset or press hands free key 5 3 Call Log 1 Dialed Numbers 2 Received Calls 3 Missed Calls 4 Delete All MENU 3 Call Log OK 5 3 1 Dialed Numbers 1 Dialed Numbers OK View Dialed Log Max 20 num display serial number name time date and icon if it is in black list MENU Call OK ...

Page 16: ...ode to check the missed calls When the records have added up to 20 items the earliest records will be covered automatically if there are new records 5 4 Phone Setup 1 Ring Type 2 Ring Volume MENU 4 Phone Setup OK 3 Time Date 4 Date Format 5 Default Set 5 4 1 Ring Type 1 Ring Type Press key to scroll 8 music and 6 normal ring tones OK to confirm Save OK 5 4 2 Ring Volume 2 Ring Volume Press key to ...

Page 17: ...Save OK Date Format Example MM Month March Æ 03 DD Date 11 th Æ 11 YY Year 2008 Æ 08 5 4 5 Default Set 5 Default Set OK Are you sure OK system resumes to Factory Default Factory default Blacklist Whitelist cleared Password changed to 1111 Call Log reset Phone volume 10 Ring tone 1 Date format YY MM DD Input format Big capital All alarm delay 3 seconds Local alarm delay 0 seconds 16 ...

Page 18: ...d alert SMS to the mobile phone recipients and call all recipients in sequence to report alert and monitor the situation 5 5 2 Power Failure 2 Power Failure OK On Off OK Note User chooses On When AC power failure the terminal will send an alert SMS to the 1st recipient In power failure status will disappear The backup battery starts supplying power will display in LCD 5 5 3 All Alarm Delay 3 All A...

Page 19: ...et PWD otherwise you can not operate SMS Alarm or SMS Unarm 5 5 6 Edit RF Sensor 6 Edit RF Sensor OK to scroll 1 Defense Area OK Edit and Input OK Set Type Main Normal OK Save OK 2 Remote Key OK Edit OK Child Key On Off OK Save OK Note Sign V indicates set code successfully Defense area setup Edit defense area name and defense Area type XX xxxxxxxx V IV Area No Area Name Main Defense Area IV 1 14 ...

Page 20: ...r to Change PWD 6 1 Set up All Alarm When no one is at home you should alarm your house all defense areas to guard against theft fire gas leakage etc Remote Alarm by SMS Send the SMS to the device SMS replies All Armed Mode activated PWD A exp 1111A All Alarm Mode will be activated directly with after the terminal receives this SMS command displays on the LCD Alarm by Remote controller On standby ...

Page 21: ...et the Gas Defense Area and Door Window Defense Area as the main areas Local Armed Mode could be activated instantly without delay Remote Local Alarm Send the SMS to the device SMS replies Local Armed Mode activated PWD L When it s activated there will be a logo displayed on the LCD Local Alarm by Remote controller On standby mode press key on controller Local Alarmed displays on the LCD Local Ala...

Page 22: ...emote controller On standby mode press key on controller Unarmed disappear Unarm by Keyboard On standby mode press on Keyboard Input PWD OK Unarmed disappear 6 4 Alert Operation 6 4 1 Activate Alert Normal main defense area 1 14 defense area In Alarmed or Local alarmed status when the detectors send alarm the system enter Alert process Special defense area 15 16 defense area In any time the detect...

Page 23: ...me Siren starts ringing Recipient pick up the call Siren stop ringing Recipient monitor the house siren rings up to 90 s disappear the alert process end up The system is still in All alarm Local alarm Alarm delay During 90 s alert new alert can not be activated defense area reports an alarm Auto call dials to1st recipient Auto call dials to 2nd recipient Auto call dials to3rd recipient Cancel Aler...

Page 24: ...lers or the terminal to activate SOS alert Emergency A Press on remote key B Press on keypad Alert delay SOS alert ends in 90 s The system is still in former status SOS SMS is sent to the recipients automatically SMS SOS I am in danger at home Please help Recipient pick up the call Recipient monitors the house Auto call dialed to 1st recipient In 30 s no phone pickup During 90 s alert new alert ca...

Page 25: ...atically Press Key on the child controller Alarm activated SMS automatically to 1st Recipient I have left the house X Press Key on the child controller Unarm activated Auto SMS to 1 st Recipient I have returned home safe x 7 2 Work recording When all Remote controllers Max 5pcs have been set for report use employees press the controller keys to send SMS to their manager as 1st Recipient automatica...

Page 26: ...hoose Type Main Normal OK Step according to Instruction Turn on sensor LCD read Rec Code xxxxxx Turn off the sensor and press 错误 链接无效 Repeat the previous steps again Turn on the sensor and press the related RF code will be saved To create new Remote controller Maximum 5 remotes are supported The remote controllers will be listed in the menu 2 Remote Key OK Edit OK Steps according to Instruction pr...

Page 27: ...llers Install the related batteries into the sensors and try to activate the sensors Then test them in MENU ME T NU 5 Alarm Setup ok PWD 7 RF Code Query OK urn On Detectors Or Press Controller Display Detectors and Remote Controllers defense area status 3 Detectors Door Window sensor Specification Z Power requirements DC 12V 8 4V A23 DC 12V battery inside Z Current consumption less than 20μA Less ...

Page 28: ...red door window It is better if the distance between them is closer less than 15mm between part A and part B Double Faced Tape Use You should better pull out the antenna wholly and then open the monitored door window It is all right that the work LED shows At the same time the host will alarm If the work LED doesn t show or host doesn t alarm please check whether the low power LED is show If yes p...

Page 29: ...crew and mount the detector The idea height recommended is about 2 1m and keep the detector face downward with an included angel of 6 12 against the wall To avoid false alarms and maintain a normal working condition keep the detector away from air conditioner electrical fan window or other objects such as refrigerator oven etc which may bring on the change of temperature Do not aim at heat sources...

Page 30: ...11111 Fig 1 Coverage Range and Appearance Fig2 Sensitivity detection of PIR Detector Low power indication When the LED turns into green it means the battery within the detector is weak and must be replaced The detector will stop emitting signals 29 ...

Page 31: ...Battery model CR123A High capacity lithium cell 30 ...

Reviews: