22
A
D
V
A
N
C
ED
A
DVANCED
P
ROGRAMMING
A
DD
T
EMPERATURE
The Add Temperature feature adds temperature in 5 °F (3 °C) increments to the temperature in segment two. This is
considered the Process Temperature since it is holding at the peak temperature of the program. You will only be able to ac-
cess this feature when the program is currently in the Segment 2 Hold. To verify the current segment, use the View Segment
Feature. It should display HLd2.
Press
while the program is in Hold 2. The display will read the current segment then display EdIt for approximate-
ly 6 seconds.
Press
while EdIt is displayed. The display will then show SSEG for 6 seconds.
Press
while SSEG is
displayed, to advance it to tME and then
Press
again to display tMP.
Press
to add 5 °F (3 °C) to the Process Tem-
perature. The display will then return to showing the current temperature alternately with the Hold Time. The Hold Time
will not reset so you may need to use the Add Time Feature to allow it enough time to reach the new temperature.
L
OAD
M
ODE
L
OADING
A S
TORED
R
AMP
AND
H
OLD
P
ROGRAM
It is possible to store up to fi ve Ramp and Hold (PRO) programs in the GlassMaster LT. In order to recall a program
from memory perform the following steps:
Make sure the controller is in the Advanced State. From Idle
Press
to access the Mode menu. Use the
or
keys
to select “LOAD” and then
Press
.
The display will show the last Ramp and Hold (PRO) program selected. Use the
or
to select a program number
and press
to Load the program.
The display will now read “REDI”. Press
to start the program or
to Review it fi rst.
O
PTIONS
M
ODE
E
DITING
F
ACTORY
S
ETTINGS
The Options Mode allows you to toggle on or off Modify Glass Fire Mode and toggle between Fahrenheit and Celsius
Temperature Scales. It also allows you to RESET all of the factory settings to their original values. Remember when you
use the RESET feature it will clear out all of the Ramp and Hold Programs that you have stored (there is a factory set casting
program that will be restored in Program 6), change the temperature scale to Fahrenheit, and reset any adjustments you may
have made in Modify Glass Fire Mode. To access these Options features follow these instructions:
Make sure the controller is in the Advanced State. From Idle
Press
to access the MODE menu. Use the
or
keys to select “OPt” and then
Press
.
Use the
or
to select the feature you wish to edit and press
to select it.
Use the
or
to toggle to your selection and press
to select it. For RESET simply press
to select it.