8
S
ETUP
S
TEP
7 - T
ESTING
THE
E
NVIRO
V
ENT
2
FOR
PROPER
OPERATION
Check to make sure the plenum cup has not shifted
during installation. It should be perpendicular to
the fl oor and have a good seal to the bottom of the
kiln.
Plug the EnviroVent2 power cord into a 110 - 120
volt outlet.
Turn on the blower by activating the switch in the
power cord. Ensure that the blower motor starts
and operates normally. If the blower doesn’t start
or the sound of air passage is not evident, immedi-
ately unplug the blower and check for the cause of the malfunction.
Close the lid of the kiln.
Install all peep plugs.
Ensure that no other kiln openings are left open except the drilled holes in the kiln lid.
Test your new vent system by placing a lighted match directly over and level with one of the lid holes. The
fl ame from the match should be pulled into the kiln as a result of the draft. If you are unsure of the effect of
the draft, observe the action of the fl ame away from the hole and then move it over the hole. If the fl ame is
not pulled into the kiln, the kiln is not venting properly. See page 13 on Troubleshooting. Repeat this test
regularly to ensure continuing accurate operation.
T
ESTING
P
REVIOUSLY
D
RILLED
L
IDS
As mentioned earlier it may not be necessary to patch existing holes. If there are more holes, or holes with a
larger diameter than this manual recommends in your kiln lid, you may not be able to fl ame test it as previously
recommended. If a fl ame is not drawn through the lid try covering up some of the holes in the lid. If after cover-
ing all the holes in the lid you still cannot get a fl ame to draw down into the chamber, contact your distributor for
further instruction.
C
HECKING
T
HE
P
LENUM
C
UP
The fl oor of a 12 sided kiln will fl ex up to 1/4” due to the uneven heating of the fl oor. The spring loaded action
of the EnviroVent2 will allow the plenum cup to rise and fall with the fl exing of the kiln fl oor. If the 3” aluminum
fl ex is kicked, bumped or otherwise dislodged, the position of the plenum cup may change. If this occurs, simply
look at the plenum cup to ensure it is positioned properly. To reposition the plenum cup simply push down on
the cup to release the spring pressure, reposition the cup and let go.
•
•
•
•
•
•
•