DOL 100 digital box
6
Technical User Guide
2 Product survey
130183 DOL 100 digital 8l box
130184 DOL 100 digital 16l box
External I/O box for connection of of water meter, egg counter or capacitive
sensor.
The DOL 100 converts the signal into digital signals and transmits them to
the controller using CAN bus communication.
Standard software / hardware of the DOL 530/630 series supports 13 I/O
modules in total. DOL 100 is counted in as one module.
0-24 V inputs terminals: 8 or 16.
Is used with the data network module (132244) and a CAN bus cable
(130121-130128)
2.1 Accessories
132244 Data network module w. CAN bus
Always use the data network module when using external CAN bus com-
munication.
One for each controller.
130121 CAN bus cable 50 m
130125 CAN bus cable 100 m
130126 CAN bus cable 250 m
130122 CAN bus cable 500 m
For indoor use.
Use these cables in connection with external units using the CAN bus com-
munication.
130123 CAN bus cable UV 50 m
130127 CAN bus cable UV 100 m
130128 CAN bus cable UV 250 m
130124 CAN bus cable UV 500 m
For outdoor use.
Use these cables for external units that apply CAN bus communication and
for extending silo load cell cables.