DOL 100 digital box
Technical User Guide
21
7 Technical Data
Electrical Setup
Operating voltage
V AC
90 – 264
Max. power
W
75
Max. power consumption
A
0.7
CAN bus
Protocol
CANopen in accordance with CiA301 and CiA401
Baud rate (fast)
Kbd
125
Max. cable length
m
400
Input terminals 8 digital
Low
V
< 6
High
V
> 12
Input impedance
kOhm
24
Max. input frequency
Hz
500
Puls width min.
ms
1
Outputs for power supply to egg counter and capacitive sensor
Voltage
V dc
24
Max. current
A
1.9
Mechanical
Material
ABS
Cable knock-out holes
20 x M25 For metrical cable glands
Environment
Temperature, operation
°C
0 – 50
Protection class
IP
54
Shipment
Dimensions (H x W x D)
mm
381x400x170
Dimensions crated H x W x
D
mm
395x415x206
Weight
g
3520
Shipping weight
g
4560