DOL 100 I/O Box

Technical User Guide

604373 • 2019-07-01

English 

For other language variants of this document we refer to:

Español 

Para otras variantes del idioma de este documento, visite:

Français 

Pour les versions dans d'autres langues de ce document veuillez consulter:

http://docs.skov.com/1174

Summary of Contents for DOL 100 I/O box 10RL

Page 1: ...19 07 01 English For other language variants of this document we refer to Espa ol Para otras variantes del idioma de este documento visite Fran ais Pour les versions dans d autres langues de ce docume...

Page 2: ......

Page 3: ...ual may be reproduced in any manner whatsoever without the expressed written permission of SKOV A S in each case All reasonable efforts have been made to ensure the accuracy of the information contain...

Page 4: ...tallation guide 9 4 1 Electrical connection 9 4 2 Cable routing 9 4 3 CAN bus module 10 4 4 I O type 15 11 4 5 Connection of CAN bus cable in DOL 100 12 4 6 Setting up the DOL 100 in the controller 13...

Page 5: ...es used for water flushing The DOL 100 converts the signal into digital signals and transmits them to the controller using CAN bus commu nication The DOL 100 I O box is available in two variants DOL 1...

Page 6: ...ne module DOL 100 I O box 20 RL counts as two modules Is used with the CAN bus module 132245 and a CAN bus cable 130121 130128 2 1 Accessories 132245 CAN bus module Always use the CAN bus module when...

Page 7: ...uide 3 1 Recommended tools Below follows a list of tools recommended for installation of the DOL 100 Item Description Cordless drill Screwdriver bits Utility knife Multimeter Tape measure Side cutter...

Page 8: ...DOL 100 I O Box 8 Technical User Guide 3 2 Mounting on wall Mount the DOL 100 digital box on the wall us ing four screws...

Page 9: ...dard EN 60204 1 and any other EU standards that are applicable in Europe The installation of a power supply isolator is required for each motor and power supply to facilitate voltage free work on the...

Page 10: ...bus CAN low white CAN bus GND green CAN bus B Shield termina tion Used for termination of the shield braided shield in CAN bus cable C CAN EXT TERM OFF ON CAN bus termination If DOL 100 is the last n...

Page 11: ...e jumper must be ON on the module where communication ends Type 15 1 Type 15 2 DOL 100 I O 10RL Jumper setting ON Address 7 DOL 100 I O 20RL Jumper setting OFF Ad dress 7 Jumper setting ON Address 8 B...

Page 12: ...ply CAN bus connection see dimensions below CAN_Hi brown CAN_Lo white CAN GND green Strip the cable so the shield can be connected to the DOL 100 when mounting in the connection terminal As illustrate...

Page 13: ...for water flushing The DOL 100 I O box 10RL counts as one module The DOL 100 I O box 20RL counts as two modules The software supports up to 13 I O modules Here you see the CAN bus address CAN ID and i...

Page 14: ...ower supply to the controller two wire cable including earthing contact B Max 400 m CAN bus communication cable between the DOL 100 I O box and the controller The CAN bus cable connecting all units of...

Page 15: ...DOL 100 I O Box Technical User Guide 15 4 8 Circuit diagram 4 8 1 DOL 100 I O and water flushing Flushing valve Flushing valve Flushing valve Flushing valve DOL 100 I O...

Page 16: ...e 5 Cleaning The DOL 100 box is maintenance free but should be kept free of litter and dirt Clean the product with a cloth that has been wrung out almost dry in water and avoid using high pressure cle...

Page 17: ...AN bus Check that the CAN bus cable is connected correctly and that power is being supplied to the production controller DOL 100 does not appear as con nected in the production controller Check that t...

Page 18: ...c Max voltage current at inductive load 250Vac 2Aac CAN bus Protocol CANopen in accordance with CiA301 and CiA401 Baud rate non adjustable Kbd 125 Max cable length m 400 Mechanical Material ABS Cable...

Page 19: ...DOL 100 I O Box Technical User Guide 19 7 1 Dimensioned sketch...