Operation
User Manual
SKOPE BME ActiveCore
Door Switch
Each door is fitted with a door switch which tells the electronic controller
when the door is opened and closed. If the door is opened for over two
minutes an alarm will sound. Press the set (mute) button on the electronic
controller to mute the alarm.
Temperature
Setpoint
The chiller temperature setpoint is factory set at 2.5°C for storage of
perishable products (all shelves maintain temperatures below 5°C). The
cabinet setpoint can be adjusted between 1°C and 15°C for other specialist
applications if required (see below).
SKOPE do not recommend that the setpoint be changed unless it is
absolutely necessary, and then only by small increments at a time.
To view and adjust the temperature setpoint
Messages and
Alarms
The following table explains messages and alarms that the electronic
controller displays.
1. Press and hold the
set
button for 3 seconds until
PS
is
shown on the display, indicating entry into the controller
settings menu.
2. Press the
up
or
down
button to scroll the menu until
St
is shown on the display.
3. Press the
set
button. The current setpoint value is shown on the display.
4. Press the
up
or
down
button to increase or decease the setpoint value to the
required temperature.
5. Press the
set
button to temporarily save the setpoint value.
6. Press and hold the
set
button for 3 seconds to permanently save the setpoint
value and exit the controller settings menu.
Display
Description
Message: The chiller is in ‘Normal’ mode and the electronic
controller displays the chiller temperature.
Message: The chiller is in ‘Energy Saving’ mode. When in
Energy Saving mode the temperature inside the chiller is
moderated and the cabinet lights turn off. The lights can be
switched on and off by pressing the light button on the
controller faceplate, and the chiller can be switched into
‘normal’ mode by pressing the Energy Saving button on the
electronic controller faceplate.
Alarm: The front door has remained open for over two minutes.
An alarm sounds, and the compressor and evaporator fan turn
off.
Alarm: Probe failure. A temperature probe has failed and an
alarm sounds. Contact a service agent.
Alarm: There is a refrigeration system error and the controller
turns the chiller off to avoid damage. An alarm sounds, and the
compressor and evaporator fan turn off. Contact a service
agent.