background image

BB380r-2, BB580r-3, BB780r-4

SKOPE Backbar Remote Chillers

1

SPECIFICATIONS

1.1

Cabinet and Refrigeration Unit  . . . . . . . . . . . . . . . . . . . . . . . 6

2

INSTALLATION

2.1

Positioning of Machine  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2.2

Refrigeration System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3

OPERATION

3.1

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.2

Operation of Machine  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3.3

Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3.4

Cleaning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3.5

Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

4

ELECTRONIC CONTROLLER

4.1

Controller Display  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

4.2

Controller Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

4.3

Programming Controller  . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

4.4

Parameters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

4.5

Display Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

TABLE OF CONTENTS

iii

Summary of Contents for BB380r-2

Page 1: ...BB380r 2 Door BB580r 3 Door BB780r 4 Door SKOPE Backbar Remote Chillers Horizontal Display and Storage Installation and Operating Instructions MAN0706 Rev 1 0 Dec 2003 edition Model BB380r 2SW...

Page 2: ......

Page 3: ...3 983 3896 E mail enquiry skope co nz Website www skope co nz Australia SKOPE AUSTRALIA PTY LTD A C N 000 384 270 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121...

Page 4: ...rating Instructions MAN0706 Rev 1 0 Dec 2003 edition Published by SKOPE Industries Limited Christchurch New Zealand Copyright 2003 SKOPE Industries Limited All rights reserved SKOPE and CYCLONE are re...

Page 5: ...itioning of Machine 7 2 2 Refrigeration System 9 3 OPERATION 3 1 Safety Information 11 3 2 Operation of Machine 12 3 3 Loading 12 3 4 Cleaning 13 3 5 Servicing 13 4 ELECTRONIC CONTROLLER 4 1 Controlle...

Page 6: ...600mm with bench top Depth Pass Thru 655 670mm with bench top Floor area 0 81m2 1 14m2 1 48m2 Internal volume 380 litres 580 litres 780 litres Electrical Power supply 220 240 V a c 50 Hz single phase...

Page 7: ...warm draughts etc Maximum recommended operating ambient temperature is 32 C at 65 RH and for tropical machines is 40 C at 75 RH Adequate allowance should be made for door opening The chiller must be...

Page 8: ...m and swing open 2 Pull the mains flex fully out from the unit compartment and remove the rubber band 3 Push the unit end of flex into the grey plastic clip beside the front cover bottom hinge and clo...

Page 9: ...solenoid No solenoid is supplied with the remote unit Refrigeration Practice Installation must be performed by a refrigeration tradesperson to an appropriate standard complying with all local regulati...

Page 10: ...ug The cabinet lighting and centre pillar heater elements are protected by a 3 Amp fuse located in the unit junction box If a solenoid is fitted and controlled by the electronic controller the solenoi...

Page 11: ...ot to touch moving parts and hot surfaces Do NOT cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit Do NOT probe any opening Regulations re...

Page 12: ...nternal cabinet air will continue to circulate at all times The light switch located next to the electronic controller on the refrigeration unit front cover activates the cabinet interior lighting and...

Page 13: ...ower supply before washing the cabinet with water Do not wipe the sealant off the swing door gaskets as the sealant ensures the door gaskets form a good seal with the cabinet Caution Disconnect machin...

Page 14: ...UP Press to see the maximum stored temperature In programming mode it browses the parameter codes or increases the displayed value 4 DOWN Press to see the minimum stored temp In programming mode it br...

Page 15: ...ure between 1 C and 4 C For compressor protection the control has built in minimum off cycle time of 3 minutes and features regular timed defrost cycles compressor off evaporator fans on Probe One is...

Page 16: ...int it will be possible only to see the Set Point or maximum or minimum temperature stored 3 If a key is pressed for more than 3 seconds the PoF message will be displayed To display the Set Point Pres...

Page 17: ...SET key to store the new value and move to the following parameter 6 To exit Press both the SET and UP keys or wait 15 seconds without pressing any keys 7 To lock in new parameter value after one minu...

Page 18: ...0 0 DO NOT ADJUST AC 3 3 DISPLAY PARAMETERS CF C C DO NOT ADJUST rES dE in LoD P1 P1 DEFROST PARAMETERS IdF 6 6 1 to 120 hours Interval between defrost cycles MdF 12 12 0 to 255 minutes Maximum length...

Page 19: ...ers by replugging the cabinet power supply or isolation switch In this case all the alarms are reset Alarm Description Stage ONE Maintenance required Immediately attend condenser for auto alarm reset...