Getting started with the DL850-270 

 

 
This guide is a compressed version of the 
information found in the manuals ‘DL850 
Operation and Installation Manual’, and 
‘100mm Gate Valve for DL850 Operation and 
installation manual’ 

 

The diagrams can be found in greater detail in 
these manuals. 
 
The system comprises of 4 sections: 

 

The bridge unit 

 

The transceiver 

 

The transducer 

 

Cabling 

 
The Unit is supplied with terminated cable for 
the transducer, and yard stock cable can be used 
for the longer transceiver – bridge section 
(individually screened twisted pair). 
Alternatively, this cable can also be provided by 
Skipper part nr 

ZZK-01011

 

Mounting the bridge unit  

1.

 

The bridge unit is mounted in or near 
the bridge, allowing a space for the air 
to escape at the back of the cabinet 
(>10mm). The bridge unit will accept 
24VDC or 115/230V AC. Power 
cables are not provided. 

 

2.

 

Mount the unit using the 3 screws on 
the rear (provided) or using the 
skipper bracket ordered separately 
part nr ZZA-01125 (photo), 
alternatively a flush mount bracket 
can be ordered ZOA01042. Open the 
cabinet, using a Phillips (cross) 
screwdriver. Screw the power lines to 
the appropriate terminals pt1 or pt 2 
(or both). If AC is used, select the correct voltage 
using connecter pt 3 or pt 4 (unit supplied in 

230V position) 

 

 

Point 6 

Earthing 

Point 4 

230V 

Point 3 

115V 

Point 1 

DC 

Point 2 

AC 

Point 5 
switches 

 

 

3.

 

Ground the unit to ship ground using the grounding terminal (pt 6) 

 
 