Operation and Installation CD401MR-SB
Edition: 2011-12-19 Rev: 1.11
Page 14 of 52
s
etUp
of
inpUts
The system will allow many NMEA formats to be displayed. The system will
automatically update recognized formats.
c
hAnging
of
the
bAUD
rAte
The NMEA (IEC61162-1) standard is 4800 baud. Some vessels run with higher baud
rates. 4800, 9600, 19200, 38400, 57600 and 115200 baud rates can be selected in the
baud screen of the setup menu.
D
emo
moDe
A demo mode is available, and can be activated with MENU button in the diagnostics
menu. Two modes are available.
• Mode 1
is a dynamic demo mode taking the present value as the start point and
slowly varying all the available values.
• Mode 2
is a static mode taking the present values and keeping them active.
• Mode 3
is a
fixed speed
longitudinal 5 kn, transversal 1 kn.
When the demo mode is active, alarms will be disabled, and the screen will indicate the
demo state with a blinking S in the upper right corner. The user can turn off the demo
mode from the demo screen, or by recycling the power. The demo mode will turn off
automatically after 10 hours.
m
Aster
r
eset
(f
Actory
D
efAUlt
s
ettings
)
The factory default settings can be restored by performing the following operations:
1. Select CODE in diagnostic (DIAG) menu.
2. Press the SET button (
note
: Do not change code value).
The unit will now restart with factory default settings.